Accommodation and the third spatial harmonic.

Abstract

PURPOSE: Mathews and Kruger recently reported that accommodative tracking of sine wave grating targets is best between 1 and 7 cpd. Their study suggests that the spatial third harmonic might not enhance the accommodative response if the fundamental is higher than roughly 2 cpd. This study tested the effect of adding the third harmonic with targets that included 1, 3, and 5 cpd fundamental sine wave gratings, compound gratings with the third harmonic of each of these fundamentals added in either peaks-add or peaks-subtract phase, as well as each third harmonic presented alone at one-third of the contrast of the fundamental gratings. METHODS: Accommodation was monitored continuously with a dynamic infrared optometer while the subject viewed the gratings in a Badal stimulus system. Dioptric vergence changed sinusoidally over a 2.00 or 0.50 D range at 0.2 Hz. A Fast Fourier Transform extracted the amplitude and phase of each response at the temporal frequency of the stimulus. RESULTS AND CONCLUSIONS: The third harmonic enhanced the accommodative response only when the fundamental was 1 cpd. This was true at both amplitudes of target motion. This contradicts models that suggest that high spatial frequencies are used to refine the accommodative response. Second, the responses to the peaks-add and peaks-subtract phase conditions were essentially the same for each fundamental. This suggests that the effect of harmonics cannot be described by any simple linear relationship between the increased luminance gradient of the grating target and the accommodative response. Third, the accommodative response to gratings with a 5 cpd fundamental were smaller than the responses to gratings with the 3 cpd fundamental. This contradicts the gradient hypothesis of accommodative control inasmuch as the luminance gradient is steeper in the gratings with the 5 cpd fundamental. Alternatively, it seems that harmonics will enhance an accommodative response regardless of phase if they are effective accommodative stimuli on their own.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Mathews. 1998. Accommodation and the third spatial harmonic.. https://doi.org/10.1097/00006324-199806000-00029

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Conceptual model of human blur perception.

An empirically based, conceptual model of human blur perception is presented. It incorporates the concepts of blur detection and blur discrimination in depth, and across the central and peripheral retina, in two- and three-dimensional visual space. Key aspects of the model are its dynamic nature, predictability regarding the blur-based depth-ordering of objects, patterns of retinal defocus with far and near viewing, and interactions related to retinal defocus between the central and peripheral retina. Furthermore, a two-dimensional schematic representation of the blur-free region during near viewing is depicted in dioptric space. This model has implications with respect to accommodative control, depth perception, and refractive error development and progression.

Accommodation, Ocular↗

The effect of human in vivo accommodation on crystalline lens stability.

AIM: To determine the effect of human in vivo accommodation on the stability of the crystalline lens. METHODS: Using a dual Purkinje image (DPI) eyetracker, the phase-time difference and amplitudes of Purkinje images I (P(I)) and IV (P(1V)) were measured in 37 normal emmetropic subjects (34 women and 3 men; mean age 19.8, range 18-22 years) when they changed focus from 70 to 15 cm and simultaneously rotated their heads horizontally from side to side or made horizontal saccades between two targets 6.8 degrees apart. RESULTS: When the subjects changed focus from 70 to 15 cm and rotated their heads or made eye saccades, the phase-time difference between P(I) and P(IV) decreased. During saccades, the amplitude of both P(I) and P(IV) overshoots significantly increased with focus at 15 cm; however, their ratio (P(IV) overshoot amplitude/P(I) overshoot amplitude) significantly declined. CONCLUSIONS: The lens is stable during accommodation. The implications of these findings on the mechanism of accommodation are discussed.

Accommodation, Ocular↗

Synchrony dual-optic accommodating intraocular lens. Part 2: pilot clinical evaluation.

PURPOSE: To evaluate the clinical outcomes of an accommodating dual-optic intraocular lens (IOL). SETTING: Private practice and university centers. METHODS: A prospective noncomparative case series with retrospective control comprised 21 patients (26 eyes) scheduled for small-incision extracapsular cataract extraction by phacoemulsification with implantation of the Synchrony dual-optic accommodating IOL (Visiogen) (accommodating IOL group) and 10 patients who had small-incision extracapsular phacoemulsification with implantation of a monofocal, single-optic IOL at least 6 months previously (control group). Patients were examined 1, 3, 6, and 12 months after surgery. Defocus curves in the accommodating IOL group were compared with those in the control group. The main outcome measures were postoperative distance uncorrected and best corrected visual acuity; near uncorrected, distance corrected, and near corrected visual acuity; and accommodative range based on defocus curves. RESULTS: Twenty-four eyes were available at the 6-month follow-up visit. All eyes had best corrected distance visual acuity of 20/40 or better, and 19 eyes (79%) had an uncorrected distance visual acuity of 20/40 or better. Uncorrected near visual acuity was 20/40 or better in all eyes. With distance correction, 23 eyes (96%) had an acuity of 20/40 or better at near. Defocus curve analysis suggested a mean accommodative range of 3.22 diopters (D) +/- 0.88 (SD) (range 1.00 to 5.00 D) in the accommodating IOL group and 1.65 +/- 0.58 D in the control group (range 1.00 to 2.50 D) (P<.05). CONCLUSION: The Synchrony dual-optic IOL shows promise as an option to provide accommodative function in pseudophakic patients.