Search PubMedSearch

PubMed · 9573877

Orthodontic wire: a continuing evolution.

Abstract

Wires have substantial structural presence in active and retentive orthodontic therapy. Wires, and auxiliaries fabricated from wire, may deliver force to produce dental displacements, they may attempt to prevent unwanted displacements, or they may simply carry force from one location to another within the dentofacial complex. Wires may have relatively simple or rather convoluted geometries. The most prominent wire in clinical orthodontic treatment is the "arch wire." Marketed in just two, symmetrical, cross-sectional shapes, its sizes are numerous, and arch wires are manufactured of a variety of metallic alloys and compositions. The primary objective of this article is to trace the history of arch wires over the past century, considering the evolution from the stiff arch bow to the wire exhibiting Hookean material behavior, from the precious metal to the stainless steel to the titanium alloys, and into the era of the "superelastic" wire and a thermomechanical behavior decidedly more complex than its predecessors. Timely, relevant questions that are addressed herein pertain to the current "state-of-the-art" of orthodontic wires, the extent to which the mechanics of the "old" and new wires are understood, and the anticipated arch wire advancements in the near future as a new millennium approaches.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R J Nikolai. 1997. Orthodontic wire: a continuing evolution.. https://doi.org/10.1016/s1073-8746(97)80066-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Clinical evaluation and microstructural analysis of a direct placement gallium restorative alloy.

OBJECTIVES: The objective of this study was to assess the clinical performance of a direct placement gallium alloy sealed with an established dentine adhesive system. In addition, microanalysis of a few gallium restorations that failed in clinical service was performed. Clinical factors such as pulpal sensitivity, fracture of the restoration and of the tooth, marginal deterioration, and tarnish were assessed. METHODS: Sixty-five restorations of Galloy and 62 of Tytin (49 and 51 Class II restorations, respectively) were placed according to a predetermined scheme for randomisation in 37 patients by two operators using rubber dam isolation. For the Galloy restorations, the enamel and dentine were etched, and then sealed with PAAMA 2 dentine adhesive according to the manufacturer's instructions. After carving, PAAMA 2 was applied to the Galloy and light-cured. Cavity preparations for Tytin received no adhesive sealer. All restorations were polished at least 24 h post-operatively. Microstructural analysis of retrieved fragments of failed restorations was conducted using electron probe microanalysis. RESULTS: At 1 year, only one Tytin restoration was found to have failed due to an isthmus fracture. The remaining restorations of Tytin were intact with no reported sensitivity. Of the 65 Galloy restorations placed, 28 had to be removed, including restorations in teeth, which were symptomatic, non-vital and/or fractured, and teeth with fractured restorations. Tarnish was present on many of the Galloy restorations. Retrieved fragments of failed Galloy restorations exhibited a dark surface at the pulpal wall interface and small cracks were observed in that surface. Internal cracks and extensive corrosion was observed using the microprobe. Gallium oxides and chlorides were identified as the predominant corrosion products. CONCLUSIONS: The gallium alloy, Galloy, sealed with PAAMA 2 dentine adhesive system demonstrated a high clinical failure rate.

Dental Alloys

The effect of surface treatments of nickel-titanium files on wear and cutting efficiency.

OBJECTIVES: This study was designed to verify whether nitridation treatment of the cutting surfaces resulted in surface or subsurface changes that produced an increase in the resistance to wear in nickel titanium (NiTi) endodontic files. STUDY DESIGN: Some experimental samples were exposed to ionic implantation by using 150 keV of nitrogen ions and doses of 1 x 10(17) ions per cm(2). Other samples were exposed to thermal nitridation processes performed for 480 minutes at 500 degrees C temperature. Control samples were not exposed to any process. The chemical composition of the surface layers of each sample was determined by means of x-ray photoelectron spectroscopy. The cutting efficiency was tested on an endotraining bloc. RESULTS: The experimental instruments showed in-depth distributions of chemical composition that were different from those seen in the control group; thermal-nitridated instruments demonstrated a surface ratio of nickel to titanium of 0.5. Implanted samples had a higher N/Ti ratio (1.2); this ratio may be due to the presence of a layer of titanium nitride. Samples in the experimental groups showed an increase in cutting ability as compared with the controls. CONCLUSIONS: Thermal nitridation and nitrogen-ionic implantation treatment of nickel-titanium files produced a higher wear resistance and an increased cutting capacity.

Dental Alloys