Search PubMed⌕ Search

PubMed · 9552446

Research in solid dosage forms--an obsolete topic?

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Leuenberger. 1997. Research in solid dosage forms--an obsolete topic?. https://doi.org/10.3109/10837459709031438

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Improvement in the disintegration of shellac-coated soft gelatin capsules in simulated intestinal fluid.

Shellac is a natural enteric polymer, which results in good gastric resistance; however, it often dissolves too slowly in intestinal fluids. The objective of this study was to improve the disintegration of shellac-coated soft gelatin capsules in simulated intestinal fluids (phosphate buffer pH 6.8) through the addition of pore-formers, such as organic acids and hydrophilic polymers, while retaining gastric resistance. The mechanical properties (% elongation at rupture, puncture strength at break and modulus at puncture), media uptake and weight loss of shellac films were determined upon exposure in 0.1 N HCl and/or phosphate buffer pH 6.8. Organic acids (e.g., sorbic acid) acted as plasticizers, they reduced the glass transition temperature of ethanol-cast shellac films. The addition of additives effectively decreased the disintegration times in phosphate buffer pH 6.8, while the behavior in 0.1 N HCl remained unchanged. In addition, the hardness and disintegration of shellac-coated soft gelatin capsules were monitored through the whole disintegration experiments. The best disintegration was achieved with sorbic acid as pore-former. Sorbic acid remained in the shellac coating at low pH, but leached in pH 6.8 buffer, thus resulting in good gastric resistance and rapid disintegration in simulated intestinal fluids. The disintegration time of ethanolic shellac-coated soft gelatin capsules decreased with increasing amount of pore-former. The slow disintegration of aqueous shellac-coated soft gelatin capsules could be also improved by the addition of hydrophilic polymers, such as hydroxypropyl methylcellulose (HPMC). However, higher HPMC concentrations were required when compared to sorbic acid.

Capsules↗

Is the use of a 200 ml vessel suitable for dissolution of low dose drug products?

This work evaluated the use of a commercially available 200 ml vessel for dissolution of five drug products with various solubilities. Each of the five drug products (four with USP monographs and one proprietary tablet formulation) was run at four different conditions (USP 25 monograph, six dosage units in single 1l vessel, 200 ml at the USP Monograph speed, and 200 ml at calculated paddle speed which matches the hydrodynamics of the USP vessel). Six dosage units in a single vessel were used as a comparison to increase the drug concentration for dissolution testing. Due to the different dissolution hydrodynamics, drug dissolution from the dosage forms was slower using the 200 ml conversion kit than when the USP method with a 1l vessel was used. However, use of the 200 ml vessel at higher paddle speeds calculated by the power/volume equation, yielded similar results as the monograph method. Thus, it appears that using the power/volume ratio calculation to obtain comparable hydrodynamics lends utility to the 200 ml vessel as a means for characterizing the dissolution profile of low dose solid oral drug products. The results of the multiple dosage units per vessel also gave similar results to that of the USP monograph method.

Capsules↗

The effect of phosphorylcholine-coated materials on the inflammatory response and fibrous capsule formation: in vitro and in vivo observations.

Several experiments were performed to compare the in vitro adhesion of human macrophage and granulocyte inflammatory cells to polyethylene terephthalate substrate and the same coated with a phosphorylcholine (PC)-based polymer. The inclusion of various types of serum at different stages in the assay indicated that protein adsorption and passivation of the surface may be responsible for reducing the number of inflammatory cells adhering to the uncoated polyethylene terephthalate controls. In all of the assays performed there was a statistically significant reduction (p < 0.05; analysis of variance) of the number of inflammatory cells adhering to the PC-coated samples, linked to the ability of these surfaces to resist protein adhesion. Implantations of PC-coated stainless steel and high-density polyethylene USP control samples were made in a rabbit intramuscular model. Histological examination of the number of inflammatory cells present around the implant sites 4 weeks postimplantation showed there were 40% less cells associated with the PC-coated samples compared with control, but this was not statistically significant. Fibrous capsule thickness, however, whereas marginally less at 4 weeks, had almost completely regressed for the PC-coated sample at 13 weeks postimplantation and was statistically thinner (p < 0.01; Mann-Whitney U test) than the high-density polyethylene USP control. These findings support the view that low biointeractions observed for PC-based technology in vitro can result in reduced inflammation and foreign body reaction in vivo.

Capsules↗