Video based lifting technique coding system.

Abstract

Despite automation and improved working conditions, many materials in industry are still handled manually. Among the basic activities involved in manual materials handling, lifting is the one most frequently associated with low-back pain (LBP). Biomechanical analysis techniques have been used to better understand the risk factors associated with manual handling, but because these techniques require specialized equipment, highly trained personnel, and interfere with normal business operations, they are limited in their usefulness. A video based lifting technique analysis system (the VidLiTeCTM System) is presented that provides for quantifiable non-invasive biomechanical analysis of the dynamic features of lifting with high inter-coder reliability and low sensitivity to absolute errors. Analysis of results from a laboratory experiment and from field-collected videotape are described that support the reliability, sensitivity, and accuracy claims of the VidLiTeCTM System. The VidLiTeCTM System allows technicians with minimal training and low-tech equipment (a camcorder) to collect large sets of lifting data without interfering with normal business operations. A reasonably accurate estimate of the peak compressive force on the L5/S1 joint can be made from the data collected. Such a system can be used to collect quantified data on lifting techniques that can be related to LBP reporting.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S M Hsiang, G E Brogmus, S E Martin, I B Bezverkhny. 1998. Video based lifting technique coding system.. https://doi.org/10.1080/001401398187017

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of gravitational load on jaw movements in speech.

External loads arising as a result of the orientation of body segments relative to gravity can affect the achievement of movement goals. The degree to which subjects adjust control signals to compensate for these loads is a reflection of the extent to which forces affecting motion are represented neurally. In the present study we assessed whether subjects, when speaking, compensate for loads caused by the orientation of the head relative to gravity. We used a mathematical model of the jaw to predict the effects of control signals that are not adjusted for changes to head orientation. The simulations predicted a systematic change in sagittal plane jaw orientation and horizontal position resulting from changes to the orientation of the head. We conducted an empirical study in which subjects were tested under the same conditions. With one exception, empirical results were consistent with the simulations. In both simulation and empirical studies, the jaw was rotated closer to occlusion and translated in an anterior direction when the head was in the prone orientation. When the head was in the supine orientation, the jaw was rotated away from occlusion. The findings suggest that the nervous system does not completely compensate for changes in head orientation relative to gravity. A second study was conducted to assess possible changes in acoustical patterns attributable to changes in head orientation. The frequencies of the first (F1) and second (F2) formants associated with the steady-state portion of vowels were measured. As in the kinematic study, systematic differences in the values of F1 and F2 were observed with changes in head orientation. Thus the acoustical analysis further supports the conclusion that control signals are not completely adjusted to offset forces arising because of changes in orientation.

Biomechanical Phenomena

Static and fatigue biomechanical properties of anterior thoracolumbar instrumentation systems. A synthetic testing model.

STUDY DESIGN: A mechanical testing standard for anterior thoracolumbar instrumentation systems was introduced, using a synthetic model. Twelve recent instrumentation systems were tested in static and fatigue modes. OBJECTIVES: To establish the testing standard for anterior thoracolumbar instrumentation systems using a synthetic model and to evaluate the static and fatigue biomechanical properties of 12 anterior thoracolumbar instrumentation systems. SUMMARY OF BACKGROUND DATA: Although numerous studies have been performed to evaluate the biomechanics of anterior spinal instrumentation using a cadaveric or animal tissue, problems of specimen variation, lack of reproducibility, and inability to perform fatigue testing have been pointed out. In no studies has a precise synthetic testing standard for anterior thoracolumbar instrumentation systems been described. METHODS: An ultra-high-molecular-weight polyethylene cylinder was designed according to the anatomic dimensions of the vertebral body. Two cylinders spanned by spinal instrumentation simulated a total corpectomy defect, and a compressive lateral bending load was applied. The instrumentation assembly was precisely standardized. The static destructive and fatigue tests up to 2 million cycles at three load levels were conducted, followed by the failure mode analysis. Twelve anterior instrumentation systems, consisting of five plate and seven rod systems were compared in stiffness, bending strength, and cycles to failure. RESULTS: Static and fatigue test parameters both demonstrated highly significant differences between devices. The stiffness ranged from 280.5 kN/m in the Synthes plate (Synthes, Paoli, PA) to 67.9 kN/m in the Z-plate ATL (SofamorDanek, Memphis, TN). The Synthes plate and Kaneda SR titanium (AcroMed, Cleveland, OH) formed the highest subset in bending strength of 1516.1 N and 1209.9 N, respectively, whereas the Z-plate showed the lowest value of 407.3 N. There were no substantial differences between plate and rod devices. In fatigue, only three systems: Synthes plate, Kaneda SR titanium, and Olerud plate (Nord Opedic AB, Sweden) withstood 2 million cycles at 600 N. The failure mode analysis demonstrated plate or bolt fractures in plate systems and rod fractures in rod systems. CONCLUSIONS: The biomechanical testing standard for anterior thoracolumbar instrumentation systems was successfully designed. It provided a repeatable and consistent experimental condition and controlling dimensional and surgical factors. The comparison of 12 instrumentation systems highlights the importance of mechanically balanced device design without a weak link in the development of instrumentation.

Biomechanical Phenomena