Search PubMed⌕ Search

PubMed · 9520383

How Cro and lambda-repressor distinguish between operators: the structural basis underlying a genetic switch.

Abstract

Knowledge of the three-dimensional structures of the lambda-Cro and lambda-repressor proteins in complex with DNA has made it possible to evaluate how these proteins discriminate between different operators in phage lambda. As anticipated in previous studies, the helix-turn-helix units of the respective proteins bind in very different alignments. In Cro the recognition helices are 29 A apart and are tilted by 55 degrees with respect to each other, but bind parallel to the major groove of the DNA. In lambda-repressor [Beamer, L. J. & Pabo, C. O. (1992) J. Mol. Biol. 227, 177-196] the helices are 34 A apart and are essentially parallel to each other, but are inclined to the major grooves. The DNA is much more bent when bound by Cro than in the case with lambda-repressor. The first two amino acids of the recognition helices of the two proteins, Gln-27 and Ser-28 in Cro, and Gln-44 and Ser-45 in lambda-repressor, make very similar interactions with the invariant bps 2 and 4. There are also analogous contacts between the thymine of bp 5 and, respectively, the backbone of Ala-29 of Cro and the backbone of Gly-46 of lambda-repressor. Otherwise, however, unrelated parts of the two proteins are used in sequence-specific recognition. It appears that similar contacts to the invariant or almost invariant bps (especially 2 and 4) are used by both Cro and lambda-repressor to differentiate the operator sites as a group from other sites on the DNA. The discrimination of Cro and lambda-repressor between their different operators is more subtle and seems to be achieved primarily through differences in van der Waals contacts at bp 3', together with weaker, less direct effects at bps 5' and 8', all in the nonconsensus half of the operators. The results provide further support for the idea that there is no simple code for DNA-protein recognition.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R A Albright, B W Matthews. 1998-03-31. How Cro and lambda-repressor distinguish between operators: the structural basis underlying a genetic switch.. https://doi.org/10.1073/pnas.95.7.3431

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Propagation of fluorescent viruses in growing plaques.

To study virus propagation, we have developed a method by which the propagation of the Lambda bacteriophage can be observed and quantified. This is done by creating a fusion protein of the capsid protein gpD and the enhanced yellow fluorescent protein (EYFP). We show that this fusion allows capsid formation and that the modified viruses propagate on a surface covered with host bacteria thus forming fluorescent plaques. The intensity of fluorescence in a growing plaque determines the distribution of phages. This provides a new tool to study the propagation of infection at the microscopic level.

Bacteriophage lambda↗

Combining optical tweezers and scanning probe microscopy to study DNA-protein interactions.

We present the first results obtained with a new instrument designed and built to study DNA-protein interactions at the single molecule level. This microscope combines optical tweezers with scanning probe microscopy and allows us to locate DNA-binding proteins on a single suspended DNA molecule. A single DNA molecule is stretched taut using the optical tweezers, while a probe is scanned along the molecule. Interaction forces between the probe and the sample are measured with the optical tweezers. The instrument thus enables us to correlate mechanical and functional properties of bound proteins with the tension within the DNA molecule. The typical friction force between a micropipette used as probe and a naked DNA molecule was found to be <1 pN. A 16 micro m DNA molecule with approximately 10-15 digoxygenin (DIG) molecules located over a 90 nm range in the middle of the DNA was used as a model system. By scanning with an antidigoxygenin (alpha-DIG) antibody-coated pipette we were able to localize these sites by exploiting the high binding affinity between this antibody-antigen pair. The estimated experimental resolution assuming an infinitesimally thin and rigid probe and a single alpha-DIG/DIG bond was 15 nm.

Bacteriophage lambda↗

A rapid DNA digestion system.

This paper presents a novel microfluidic DNA digestion system incorporating a high performance micro-mixer. Through the appropriate control of fixed and periodic switching DC electric fields, electrokinetic forces are established to mix the DNA and restriction enzyme samples and to drive them through the reaction column of the device. The experimental and numerical results show that a mixing performance of 98% can be achieved within a mixing channel of length 1.6 mm when a 150 V/cm driving voltage and a 5 Hz switching frequency are applied. The relationship between the mixing performance, switching frequency, and main applied electric field is derived. It is found that the optimal switching frequency depends upon the magnitude of the main applied electric field. The successful digestion of lambda-DNA using Eco RI restriction enzyme is demonstrated. The DNA-enzyme reaction is completed within 15 min in the proposed microfluidic system, compared to 50 min in a conventional large-scale system. Hence, the current device provides a valuable tool for rapid lambda-DNA digestion, while its mixer system delivers a simple yet effective solution for mixing problems in the micro-total-analysis-systems field.

Bacteriophage lambda↗