Search PubMed⌕ Search

PubMed · 9506764

Rapid urinary iodide test.

Abstract

Assessment of iodine deficiency and monitoring of iodine supplementation programs demand rapid, simple, and cost-effective methods for the determination of urinary iodide concentrations. We propose a semiquantitative rapid test, based on the iodide-catalyzed oxidation of 3,3',5,5'-tetramethylbenzidine by peracetic acid/H2O2, to yield colored products. The color of the chemical reaction is compared with color categories of a pictogram corresponding to three ranges: <100, 100-300, and >300 microg/L (<0.79, 0.79-2.36, and >2.36 micromol/L) of iodide concentrations. The test is very easy to perform and does not require any instrumentation or apparatus. Sample preparation is simple and consists of the removal of interfering substances by disposable columns, 65 x 10.5 mm, packed with purified activated charcoal. For comparison with a reference method for measuring urinary iodide, by high-performance liquid chromatography, we determined the iodide concentrations of 370 random (untimed) urine samples from consecutive patients by both high-performance liquid chromatography and the rapid test. The results obtained by both methods are in close agreement, with respect to classification of the samples according to the above three ranges, with a maximum difference of less than 5% for each range. Median (y) values of a given distribution of urinary iodide concentrations can be calculated from the percent (x) of samples below 100 microg/L (0.79 micromol/L) using the regression equation: y = 179.78 - 1.60x. This rapid test, therefore, is suited to epidemiological surveys of iodine deficiency, especially in developing countries.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Rendl, D Bier, T Groh, C Reiners. 1998. Rapid urinary iodide test.. https://doi.org/10.1210/jcem.83.3.4633

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Deficiency of dolichyl-P-Man:Man7GlcNAc2-PP-dolichyl mannosyltransferase causes congenital disorder of glycosylation type Ig.

Deficiency of the endoplasmic reticulum enzyme dolichyl-phosphate mannose (Dol-P-Man):Man(7)GlcNAc(2)-PP-dolichyl mannosyltransferase leads to a new type of congenital disorder of glycosylation, designated type Ig. The patient 1 presented with a multisystemic disorder with microcephaly, developmental retardation, convulsions and dysmorphic signs. The isoelectric focusing pattern of the patient's serum transferrin showed the partial loss of complete N-glycan side chains. In skin fibroblasts from the patient, the activity of Dol-P-Man:Man(7)GlcNAc(2)-PP-Dol mannosyltransferase was severely reduced leading to the accumulation of Man(7)GlcNAc(2)-PP-Dol, which was transferred to newly synthesized glycoproteins. Sequencing of the Dol-P-Man:Man(7)GlcNAc(2)-PP-Dol mannosyltransferase cDNA revealed a compound heterozygosity for two point mutations, leading to the exchange of leucine(158) for a proline residue and a premature translation stop with loss of the C-terminal 74 amino acids. The parents were heterozygous for one of the two mutations. Retroviral expression of the wild-type Dol-P-Man:Man(7)GlcNAc(2)-PP-Dol mannosyltransferase cDNA in patient's fibroblasts normalized the mannosyltransferase activity.

Chromatography, High Pressure Liquid↗

Accurate mass measurement using multiple sprayer nano-electrospray mass spectrometry combined with nano-scale high-performance liquid chromatography on a magnetic sector instrument.

A new technique for accurate mass measurement utilizing multiple sprayer nano-electrospray ionization mass spectrometry (nano-ESI-MS) combined with nano-scale high-performance liquid chromatography (nano-HPLC) on a magnetic sector instrument is described. Both metal-coated glass capillaries and fused-silica capillaries were used as nano-ESI sprayers. A metal-coated glass capillary was used for the introduction of the Ref. compound solution, and a metal-coated fused-silica capillary was used for connection to the nano-HPLC column. By shifting each sprayer's position relative to the sampling orifice, spectra were obtained of both the sample components as eluted from the column and reference compounds. Several standard compounds were examined and satisfactory accurate masses were obtained. Problems arising from differences in ionization efficiency between the sample and reference compounds were not observed.

Chromatography, High Pressure Liquid↗

Stability of the lactose permease in detergent solutions.

Protein stability, as measured by irreversible protein aggregation, is one of the central difficulties in the handling of detergent-solubilized membrane proteins. We present a quantitative analysis of the stability of the Escherichia coli lactose (lac) permease and a series of lac permease fusion proteins containing an insertion of cytochrome(b562), T4 lysozyme or beta-lactamase in the central hydrophilic loop of the permease. The stability of the proteins was evaluated under a variety of storage conditions by both a qualitative SDS-PAGE assay and by a quantitative hplc assay. Long-chain maltoside detergents were more effective at maintaining purified protein in solution than detergents with smaller head groups and/or shorter alkyl tails. A full factorial experiment established that the proteins were insensitive to sodium chloride concentrations, but greatly stabilized by glycerol, low temperature and the combination of glycerol and low temperature. The accurate quantitation of the protein by absorbance spectroscopy required exclusion of all contact with clarified polypropylene or polyvinyl chloride (PVC) materials. Although some of the fusion proteins were more prone to aggregation than the wild-type permease, the stability of a fusion protein containing a cytochrome(b562) insertion was indistinguishable from that of native lac permease.

Chromatography, High Pressure Liquid↗