Manual and computer-aided space analysis: a comparative study.

Abstract

Recently, computers have been used to measure key landmarks from photocopies of upper and lower study models to increase simplicity, accuracy, and informatics. This is a comparative study to evaluate the accuracy and reliability of computer-aided space analysis. Data were collected from a series of randomly selected study models. All subjects had Angle Class I molar relationships with minor malocclusions such as crowding, rotations, or diastemas. Two investigators independently measured teeth on models with a Vernier gauge that had sharpened caliper tips. Intraexaminer and interexaminer reliability was determined at 0.2 mm. All teeth, to and including the first molars, were measured. Two photocopies of each set of models were made on a photostat machine (Xerox, Japan) and were coded. A template with a ruler was used, to allow the investigator to compensate for any reduction or enlargement error during the photocopying process. The mesiodistal sizes were measured with a digitizer, and results were processed by using a dedicated computer program. Evaluations were done in a double-blind manner. The nonparametric Wilcoxon signed rank test for paired observations to compare median differences between measurements was used. Intraexaminer digitized measurements were almost identical and differed (p < 0.0001) for only one measurement. However, interexaminer manual and digitized measurements differed significantly (p < 0.001) for 20 of the 24 teeth. Nineteen of these digitized tooth measurements were smaller. The mean arch length measurements differed by 4.7 mm (p < 0.0001) in the maxilla and by 3.1 mm (p < 0.0001) in the mandible. The difference between the manual and digitized analyses may be due to the photocopying process. The inability to accurately measure a three-dimensional study cast that has been duplicated in two dimensions, convex structure of teeth, curve of Spee, tooth inclination, and tooth position may play a role. The computer-aided measuring system is reliable, but accurate mesiodistal measurements cannot be made from photocopies of dental models. Manual measurements that use a calibrated gauge produce the most accurate, reliable, and reproducible results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

U R Schirmer, W A Wiltshire. 1997. Manual and computer-aided space analysis: a comparative study.. https://doi.org/10.1016/s0889-5406(97)70234-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of free sulfite in wine by zone electrophoresis with isotachophoresis sample pretreatment on a column-coupling chip.

This work deals with the determination of free sulfite in wine by zone electrophoresis (ZE) with on-line isotachophoresis (ITP) sample pretreatment on a column-coupling (CC) chip with conductivity detection. A rapid pre-column conversion of sulfite to hydroxymethanesulfonate (HMS), to minimize oxidation losses of the analyte, was included into the developed analytical procedure, while ITP and ZE were responsible for specific analytical tasks in the separations performed on the CC chip. ITP, for example, eliminated the sample matrix from the separation compartment and, at the same time, provided a selective concentration of HMS before its transfer to the ZE stage of the separation. On the other hand, ZE served as a final separation (destacking) method and it was used under the separating conditions favoring a sensitive conductivity detection of HMS. In this way, ITP and ZE cooperatively contributed to a 900 microg/l concentration detectability for sulfite as attained for a 60 nl load of wine (a 15-fold wine dilution and the use of a 0.9 microl sample injection channel of the chip) and, consequently, to the determination of free sulfite when this was present in wine at the concentrations as low as 3 mg/l. The separations were carried out in a closed separation compartment of the chip with suppressed hydrodynamic and electroosmotic flows. Such transport conditions, minimizing fluctuations of the migration velocities of the separated constituents, made a frame for precise migration and quantitation data as achieved for HMS in both the model and wine samples. Ninety percent recoveries, as typically obtained for free sulfite in wine samples, indicate promising potentialities of the present method as far as the accuracies of the provided analytical results are concerned.

Calibration↗

Identification and characterization of Se-methyl selenomethionine in Brassica juncea roots.

The present work shows the identification and characterization of Se-methyl selenomethionine (SeMMet) as an important Se species in Brassica juncea roots when grown in the presence of Se-methionine (SeMet) as the Se source. SeMMet was isolated by liquid chromatography employing two different liquid chromatographic mechanisms: reversed-phase ion-pairing using heptafluorobutyric acid as counter ion and cation exchange using a pyridinium formate gradient (pH 3). Inductively coupled plasma mass spectrometry was used for the detection of Se. SeMMet was characterized by electrospray quadrupole time-of-flight MS in both a synthesized standard and in the roots extract using collision-induced dissociation of the selected ion. Preliminary evidence suggests that Brassica juncea may also produce dimethylselenonium propionate, although to a much lesser extent.

Calibration↗

Influence of the extraction mode on the yield of some furanocoumarins from Pastinaca sativa fruits.

Analysis of plant material is an important task in chemotaxonomical investigations, in search of plants with pharmacological activity or in standardisation of plant drugs. The choice of optimal conditions for the analysis of plant material and effect of extraction method on the yield of furanocoumarins from Pastinaca sativa fruits were examined. The following extraction methods were used in experiments: exhaustive extraction in Soxhlet apparatus, ultrasonification (USAE) at 25 and 60 degrees C, microwave-assisted solvent extraction in open and closed system (MASE) and accelerated solvent extraction (ASE). In most cases, the yield of furanocoumarins was highest by use of ASE method as well as by ultrasonification at 60 degrees C.

Calibration↗