Search PubMedSearch

PubMed · 9413861

Functional electrical stimulation.

Abstract

In the health-care professions, electrical stimulation is used for three purposes: to aid diagnosis; as a therapeutic tool; and to restore lost or damaged functions. Functional electrical stimulation (FES) and functional neurostimulation (FNS) are terms which are more or less interchangeable, and which encompass the third of these purposes. FES itself can also be conveniently divided into three classes, according to purpose: the restoration of sensor functions; the restoration of skeleto-motor functions; and the restoration of autonomic functions. Potentially, a fourth class would comprise devices restoring cognitive or psychological functions, but no such devices are clinically available as yet. The methods and devices which are currently available for providing FES are reviewed, as are the sorts of result and benefit that may be expected from them. The structure and emphasis of the review is on the clinical applications and the relevant anatomical and neurophysiological considerations and this approach is chosen for two main reasons. Firstly, the clinical, anatomical, and physiological considerations are independent of technological change and development, so they will not become quickly out of date. Secondly, the author is a clinician by profession, and an engineer only by inclination. The functional aims of FES methods will continue to develop as a result of experience gained following the introduction and use of successful devices, and these evolutionary improvements will come from within the FES programme; but the engineering embodiment of those devices may be revolutionized at any time by technological advances coming from elsewhere.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D N Rushton. 1997. Functional electrical stimulation.. https://doi.org/10.1088/0967-3334%2F18%2F4%2F001

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Predominant activation of I1-waves from the leg motor area by transcranial magnetic stimulation.

We performed transcranial magnetic stimulation (TMS) to elucidate the D- and I-wave components comprising the motor evoked potentials (MEPs) elicited from the leg motor area, especially at near-threshold intensity. Recordings were made from the tibialis anterior muscle using needle electrodes. A figure-of-eight coil was placed so as to induce current in the brain in eight different directions, starting from the posterior-to-anterior direction and rotating it in 45 degrees steps. The latencies were compared with those evoked by transcranial electrical stimulation (TES) and TMS using a double cone coil. Although the latencies of MEPs ranged from D to I3 waves, the most prominent component evoked by TMS at near-threshold intensity represented the I1 wave. With the double cone coil, the elicited peaks always represented I1 waves, and D waves were evoked only at very high stimulus intensities, suggesting a high effectiveness of this coil in inducing I1 waves. Using the figure-of-eight coil, current flowing anteriorly or toward the hemisphere contralateral to the recorded muscle was more effective in eliciting large responses than current flowing posteriorly or toward the ipsilateral hemisphere. The effective directions induced I1 waves with the lowest threshold, whereas the less effective directions elicited I1 and I2 waves with a similar frequency. Higher stimulus intensities resulted in concomitant activation of D through I3 waves with increasing amount of D waves, but still the predominance of I1 waves was apparent. The amount of I waves, especially of I1 waves, was greater than predicted by the hypothesis that TMS over the leg motor area activates the output cells directly, but rather suggests predominant transsynaptic activation. The results accord with those of recent human epidural recordings.

Electric Stimulation

Vagus nerve stimulation therapy for epilepsy in older adults.

The authors assessed the efficacy, safety, and tolerability of vagus nerve stimulation (VNS) for refractory epilepsy in 45 adults 50 years of age and older. They determined seizure frequency, adverse effects, and quality of life. At 3 months, 12 patients had a >50% decrease in seizure frequency; at 1 year, 21 of 31 studied individuals had a >50% seizure decrease. Side effects were mild and transient. Quality of life scores improved significantly with time.

Electric Stimulation

Flexion reflex responses in biceps femoris and tibialis anterior in human neonates.

Flexion reflex responses to innocuous stimulation were examined in 11 human neonates. Reflexes were seen in tibialis anterior at a shorter latency and were larger than in biceps femoris. This may be associated with the positive 'Babinski' sign and, therefore, may reflect immaturity in spinal processing in neonates.

Electric Stimulation