Respiratory function parameters in infants using inductive plethysmography.

Abstract

A signal processing technique has been developed to determine respiratory function parameters by processing displacement data obtained from the abdomen and the rib cage of infants using respiratory inductive plethysmography. The technique transforms time-variant signals into the frequency domain, where they are filtered to reduce unwanted signal components. The phase relationship between the abdominal displacement and the rib cage displacement is determined from the phases of the filtered signals. Flow-volume loops, which are currently of great interest in respiratory medicine, are obtained from waveforms representing respiratory tidal flow and respiratory tidal volume. The index of respiratory timing is determined from a waveform representing respiratory tidal flow. The technique has been verified by statistical comparison with data simultaneously obtained using pneumotachography in a clinical study involving 49 infants.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R D Selbie, M Fletcher, N Arestis, R White, A Duncan, P Helms, P Duffty. 1997. Respiratory function parameters in infants using inductive plethysmography.. https://doi.org/10.1016/s1350-4533(97)00024-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗