Search PubMed⌕ Search

PubMed · 9385111

Dynamic reliability models with conditional proportional hazards.

Abstract

A dynamic approach to the stochastic modelling of reliability systems is further explored. This modelling approach is particularly appropriate for load-sharing, software reliability, and multivariate failure-time models, where component failure characteristics are affected by their degree of use, amount of load, or extent of stresses experienced. This approach incorporates the intuitive notion that when a set of components in a coherent system fail at a certain time, there is a 'jump' from one structure function to another which governs the residual lifetimes of the remaining functioning components, and since the component lifetimes are intrinsically affected by the structure function which they constitute, then at such a failure time there should also be a jump in the stochastic structure of the lifetimes of the remaining components. For such dynamically-modelled systems, the stochastic characteristics of their jump times are studied. These properties of the jump times allow us to obtain the properties of the lifetime of the system. In particular, for a Markov dynamic model, specific expressions for the exact distribution function of the jump times are obtained for a general coherent system, a parallel system, and a series-parallel system. We derive a new family of distribution functions which describes the distributions of the jump times for a dynamically-modelled system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Hollander, E A Peña. 1995. Dynamic reliability models with conditional proportional hazards.. https://doi.org/10.1007/bf00985451

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Miniature near-infrared dual-axes confocal microscope utilizing a two-dimensional microelectromechanical systems scanner.

The first, to our knowledge, miniature dual-axes confocal microscope has been developed, with an outer diameter of 10 mm, for subsurface imaging of biological tissues with 5-7 microm resolution. Depth-resolved en face images are obtained at 30 frames per second, with a field of view of 800 x 100 microm, by employing a two-dimensional scanning microelectromechanical systems mirror. Reflectance and fluorescence images are obtained with a laser source at 785 nm, demonstrating the ability to perform real-time optical biopsy.

Computer Systems↗

Proposal for fulfilling strategic objectives of the U.S. Roadmap for national action on clinical decision support through a service-oriented architecture leveraging HL7 services.

Despite their demonstrated effectiveness, clinical decision support (CDS) systems are not widely used within the U.S. The Roadmap for National Action on Clinical Decision Support, published in June 2006 by the American Medical Informatics Association, identifies six strategic objectives for achieving widespread adoption of effective CDS capabilities. In this manuscript, we propose a Service-Oriented Architecture (SOA) for CDS that facilitates achievement of these six objectives. Within the proposed framework, CDS capabilities are implemented through the orchestration of independent software services whose interfaces are being standardized by Health Level 7 and the Object Management Group through their joint Healthcare Services Specification Project (HSSP). Core services within this framework include the HSSP Decision Support Service, the HSSP Common Terminology Service, and the HSSP Retrieve, Locate, and Update Service. Our experiences, and those of others, indicate that the proposed SOA approach to CDS could enable the widespread adoption of effective CDS within the U.S. health care system.

Computer Systems↗

Imaging tumour motion for radiotherapy planning using MRI.

Novel technology has made dynamic magnetic resonance imaging (MRI) of lung motion and lung tumour mobility during continuous respiration feasible. This might be beneficial for planning of radiotherapy of lung tumours, especially when using high precision techniques. This paper describes the recent developments to analyze and visualize pulmonary nodules during continuous respiration using MRI. Besides recent dynamic two-dimensional approaches to quantify motion of pulmonary nodules during respiration novel three-dimensional techniques are presented. Beyond good correlation to pulmonary function tests MRI also provides regional information about differences between tumour-bearing and non-tumour bearing lung and the restrictive effects of radiotherapy as well as the compensation by the contralateral lung.

Computer Systems↗