Search PubMed⌕ Search

PubMed · 9366337

Optimization of prostate biopsy strategy using computer based analysis.

Abstract

PURPOSE: We evaluated and optimized the detection of cancer by prostate biopsies. We developed a stochastic computer simulation model of ultrasound guided biopsies using mathematically reconstructed radical prostatectomy specimens. Use of this technique allows rapid evaluation of a variety of factors for their effect on prostate biopsy results. We used this model to analyze the effectiveness of sextant biopsies, which have been widely adopted in clinical practice. We also analyzed other biopsy schemes. MATERIALS AND METHODS: A total of 607 tumor foci from 180 serially sectioned whole mount radical prostatectomy specimens was mapped and digitized. The cancers had been clinically diagnosed by a variety of biopsy strategies. Simulated parasagittal sextant biopsies were performed for each case. Forty simulation runs (each consisting of a set of 6 biopsies) were performed for each prostate, with realistic random variations in sextant biopsy localization programmed in each run. Cancer detection by biopsy was considered reliable if 90% of the simulation runs for each prostate were positive for cancer. A summary algorithm was used to map the tumor foci. RESULTS: Simulation of sextant biopsies demonstrated reliably detected cancer in only 107 of 147 patients (73%) in whom total tumor volume was greater than 0.5 cc. There was little correlation between total length of cancer in biopsy cores and tumor volume. Change of biopsy angle from 30 to 45 degrees did not result in significantly increased detection rates. Similarly, placing all biopsies more laterally did not increase overall detection rates. When we mapped tumor foci from the 40 cases in which sextant biopsies did not reliably detect tumor, we found that the foci were distributed in areas not biopsied by the sextant method, that is the transition zone, midline peripheral zone and inferior portion of the anterior horn of the peripheral zone. A 10-core biopsy scheme incorporating these areas as well as the posterolateral prostate reliably detected cancer in 141 of 147 patients (96%) with total tumor volumes greater than 0.5 cc. CONCLUSIONS: Prostate cancer of significant volume can be present in areas not sampled by standard sextant biopsies. Biopsies of the transition zone, midline peripheral zone and inferior portion of the anterior horn of the peripheral zone should be considered for re-biopsy strategy after negative sextant biopsies. Sampling of these additional areas also can be incorporated in an initial biopsy scheme to increase overall initial rates of detection of prostate cancer.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M E Chen, P Troncoso, D A Johnston, K Tang, R J Babaian. 1997. Optimization of prostate biopsy strategy using computer based analysis.. https://doi.org/10.1016/s0022-5347(01)68188-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A rapid, low-dose, 13C-urea tablet for the detection of Helicobacter pylori infection before and after treatment.

BACKGROUND: A new urea breath test (UBT) has been described which uses a tablet formulation of 13C-urea with citric acid and allows breath sampling to be performed as early as 10 min after ingestion of the tablet. AIM: To assess the diagnostic accuracy of tablet-based 13C-UBTs (50 and 100 mg 13C-urea) before and after Helicobacter pylori eradication treatment, compared with an endoscopy gold standard and a conventional 13C-UBT (75 mg 13C-urea). METHODS: Two hundred dyspeptic patients underwent endoscopy, followed by tablet-based 13C-UBTs (50 and 100 mg 13C-urea) and a conventional 13C-UBT (75 mg 13C-urea). H. pylori-infected patients were prescribed treatment and asked to return 4-6 weeks after the end of therapy for repeat endoscopy and 13C-UBTs. RESULTS: One hundred and thirteen patients were infected with H. pylori. The sensitivity and specificity of the conventional 13C-UBT were both 100%; the sensitivity and specificity of the 100-mg tablet-based 13C-UBT were 100% and 98.85%, respectively. For the 50-mg tablet-based 13C-UBT, cut-off values of the difference over baseline of between 1.65 and 3.15 provided a sensitivity and specificity of 100%. At follow-up, the sensitivity and specificity of the conventional and 100-mg tablet-based 13C-UBTs were both 100%. For the 50-mg tablet-based 13C-UBT, cut-off values of the difference over baseline of between 1.49 and 1.56 gave a sensitivity and specificity of 100%. CONCLUSIONS: New 10-min 13C-UBTs using tablet formulations of 13C-urea with citric acid are reliable for the assessment of H. pylori status pre- and post-treatment.

Biopsy↗