Clinically important intermethod differences for physiologically abnormal ionized magnesium results.

Abstract

We compared physiologically abnormal low and high ionized magnesium (iMg) results determined with the AVL 988-4 (AVL, Graz, Austria) and Nova CRT (Nova Biomedical, Waltham, Mass) ion-selective electrodes (ISEs) in serum samples from randomly selected patients. A result of < 0.39 mmol/L with either ISE constituted the low magnesium group and of > or = 0.65 mmol/L the high magnesium group. Within each group we found significant differences between the iMg results. Major intermethod differences were found for samples with physiologically normal total magnesium concentration: most of the samples in the low magnesium group (83%) had abnormally low results with the Nova ISE, whereas most of the results with the AVL ISE (83%) were normal. In contrast, all results with the AVL ISE for the high magnesium group were abnormally high, but 67% of the results with the Nova ISE were normal. The agreement for the clinical interpretation of iMg results based on the reference interval for each method was only 32%. The differences in iMg results between the two analyzers must be resolved before using the iMg test as measured with ISE for patient care.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S A Cecco, E N Hristova, N N Rehak, R J Elin. 1997. Clinically important intermethod differences for physiologically abnormal ionized magnesium results.. https://doi.org/10.1093/ajcp%2F108.5.564

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Evaluation and comparison of therapeutic monitoring of whole-blood levels of cyclosporin A and its metabolites in renal transplantation by HPLC and RIA methods.

BACKGROUND: The aim of the work was to evaluate the possibility to estimate the level of cyclosporin A (CyA) metabolites as the difference of radioimmunoassay (RIA) non-specific and RIA specific methods. METHODS: Blood samples of renal transplant patients were analyzed by three different methods: RIA specific method (CYCLO-Trac, DiaSorin, USA) (RIA(SP)), RIA non-specific method (Immunotech, Czech Republic) (RIA(NS)), and high performance liquid chromatography (HPLC) method. RESULTS: Although values obtained by RIA(SP) correlated well those obtained by HPLC (RIA(SP)=0.995.HPLC+9.68; r(2)=0.962, n=448), the results of HPLC methods were lower by 8%. The values obtained by RIA(NS) were 2.57 times higher than the values obtained by RIA(SP) (RIA(SP)=0.356RIA(NS); r(2)=0.713, n=448). The ratio (CyA+CyA metabolites)/(CyA) calculated as the ratio RIA(NS)/RIA(SP) values for 42 renal transplant patients was relatively stable for each particular patient. The sum of selected CyA metabolites (M1+M17+M21) measured by HPLC correlated well with that estimated from the difference of RIA(NS)-RIA(SP): HPLC(metab)=0.921.(RIA(NS)-RIA(SP))+21.3; (r(2)=0.746, n=448). CONCLUSION: The combination of both the specific and non-specific methods for the determination of CyA presents an improved means for the TDM of CyA and CyA metabolites in renal transplant patients. Moreover, a combination of both methods can help to elucidate some unexpected events, such as the persistence of high cyclosporin blood levels.

Blood Chemical Analysis↗