Current keratoconus detection methods compared with a neural network approach.

Abstract

PURPOSE: Four videokeratographic methods for keratoconus detection were compared with a neural network approach. METHODS: A classification neural network for keratoconus screening was designed to detect the presence of keratoconus (KC) or keratoconus suspects (KCS); a separate cone severity network graded the severity of conelike topography patterns consistent with KC or KCS. Three hundred TMS-1 examinations (Tomey) were randomly divided into training and test sets. Ten topographic indexes were network inputs. Nine categories were used: normal, astigmatism, KC, KCS, contact lens-induced warpage, pellucid marginal degeneration, photorefractive keratectomy, radial keratotomy, and penetrating keratoplasty. KC was subdivided into KC1 (mild), KC2 (moderate), and KC3 (advanced). There were three outputs for the classification network (KC, KCS, and OTHER); target output values of 0 = OTHER, 0.25 = KCS, 0.5 = KC1, 0.75 = KC2, and 1.0 = KC3 were used for the severity network. RESULTS: The best-trained classification network had 100% accuracy, specificity, and sensitivity for the test set. The severity network had mean outputs (+/-standard deviation) of OTHER = 0.02+/-0.02, KCS = 0.21+/-0.05, KC1 = 0.52+/-0.17, KC2 = 0.74+/-0.12, and KC3 = 0.91+/-0.15. The severity network output for all categories was well correlated to the keratoconus prediction index (R = 0.892, P < 0.0001). The classification network had an overall accuracy and specificity significantly better (P < or = 0.005) than the Klyce/Maeda keratoconus index (KCI) test, the Rabinowitz test (K & I-S), and simulated keratometry (average Sim K). However, there were no significant differences in keratoconus sensitivity between the classification network, KCI, and K & I-S. The sensitivity and specificity of average Sim K were significantly worse than those of the other tests. The classification network had significantly better sensitivity (P < 0.001) and specificity (P = 0.025) for KCS detection than the K & I-S. CONCLUSIONS: The neural networks completely distinguished KC from KCS and from topographies that resembled KC. The network approach equaled the sensitivity of currently used tests for keratoconus detection and outperformed them in terms of accuracy and specificity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M K Smolek, S D Klyce. 1997. Current keratoconus detection methods compared with a neural network approach.. https://pubmed.ncbi.nlm.nih.gov/9344352/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Differential tissue-on-tissue lubrication by ophthalmic formulations.

Tissue-on-tissue friction testing was used to determine how instillation of hydrophilic polymer-containing formulations between the "blinking" tissues would compare with lubrication by saline, alone, or an oil-emulsion preparation. Best results were obtained for a formulation that contained active demulcents polyethylene glycol (PEG 400) and propylene glycol (PG), as well as a gellable polymer hydroxypropyl guar (HP-Guar) in a borate-buffered solution, in comparison with hydroxypropylcellulose-containing and carboxymethylcellulose-containing formulations. Superior performance of all the formulations was found for lubricating tissue-on-tissue couples, compared with metal-oxide-to-metal oxide interfaces, or metal oxide-to-tissue interfaces. A reciprocating pin-on-disc type friction/wear test device articulated the intimal faces of preserved human umbilical cord vein segments under increasing loads during simulated continuous "eye-blinking" with addition of increasing weights up to 60 g/cm2, simulating maximal eyelid force on the orbital globe. The tissue-on-tissue couples moved from liquid phase lubrication to boundary lubrication. After residual formulations were rinsed away with saline, persistence of low friction at the highest loads was indicative of formulation substantivity. Human umbilical cord vein segments were utilized in saline-wetted tissue-on-tissue couples that showed variable starting coefficients of friction in the range 0.2-0.4, producing moderate tearing and disruption of the interfacial layers above the medial collagen zone. The best-performing formulations instilled to the tissues pre-wetted with saline apparently reacted separately with each tissue face to produce a lower final and persistent coefficient of friction of about 0.05. Scanning electron microscopy and light microscopy of these guar-modified tissue specimens showed only a few superficial tissue disruptions, and some interphase swelling consistent with polymer uptake. The frictional values for lubricated couples having non-tissue members were considerably higher than the coefficients of friction measured for the similarly lubricated tissue-on-tissue couples, emphasizing the requirement that appropriate simulations are critical to obtaining clinically predictive data.

Cornea↗

Validated prediction model for the development of primary open-angle glaucoma in individuals with ocular hypertension.

OBJECTIVE: To test the validity and generalizability of the Ocular Hypertension Treatment Study (OHTS) prediction model for the development of primary open-angle glaucoma (POAG) in a large independent sample of untreated ocular hypertensive individuals and to develop a quantitative calculator to estimate the 5-year risk that an individual with ocular hypertension will develop POAG. DESIGN: A prediction model was developed from the observation group of the OHTS and then tested on the placebo group of the European Glaucoma Prevention Study (EGPS) using a z statistic to compare hazard ratios, a c statistic for discrimination, and a calibration chi2 for systematic overestimation/underestimation of predicted risk. The 2 study samples were pooled to increase precision and generalizability of a 5-year predictive model for developing POAG. PARTICIPANTS: The OHTS observation group (n = 819; 6.6 years' median follow-up) and EGPS placebo group (n = 500; 4.8 years' median follow-up). TESTING: Data were collected on demographic characteristics, medical history, ocular examination visual fields (VFs), and optic disc photographs. MAIN OUTCOME MEASURE: Development of reproducible VF abnormality or optic disc progression as determined by masked readers and attributed to POAG by a masked end point committee. RESULTS: The same predictors for the development of POAG were identified independently in both the OHTS observation group and the EGPS placebo group-baseline age, intraocular pressure, central corneal thickness, vertical cup-to-disc ratio, and Humphrey VF pattern standard deviation. The pooled multivariate model for the development of POAG had good discrimination (c statistic, 0.74) and accurate estimation of POAG risk (calibration chi2, 7.05). CONCLUSIONS: The OHTS prediction model was validated in the EGPS placebo group. A calculator to estimate the 5-year risk of developing POAG, based on the pooled OHTS-EGPS predictive model, has high precision and will be useful for clinicians and patients in deciding the frequency of tests and examinations during follow-up and advisability of initiating preventive treatment.

Cornea↗

Corneal oxygen uptake: A review of polarographic techniques, applications, and variables.

Factors that influence the polarographic measurement of the oxygen uptake of the cornea are reviewed. These factors include the technique, electrode assembly, oxygen reservoir, membrane material and thickness, oxygen tension of the corneal environment, duration of exposure to environmental conditions and time to application of the probe all influencing measured oxygen uptake rates. Subject factors include lid position, palpebral aperture size, blinking, corneal thickness, and corneal integrity. Contact lens wear influences corneal oxygen uptake, with lens material and design parameters influencing rates obtained both under static (without blinking) and dynamic (with blinking) conditions. Measurement of corneal oxygen uptake rates remains an excellent method to quantify the oxygen supply in contact lens systems that include the contact lens, the tears, and the cornea, in which oxygen flux is influenced by the thickness and diffusion characteristics of each component.

Cornea↗