[Evaluating otolith function with subjective visual vertical discrimination].

Abstract

This report summarizes our experiences with the subjective visual vertical (SVV) as a clinical neuro-otological tool. In the SVV test, patients have to orient a dim light bar in an otherwise dark surrounding earth-vertical, using a remote-control. Normal subjects in an upright position did not deviate more than 2 degrees from true vertical. After vestibular neurectomy, the SVV was consistently tilted by some 12 degrees toward the affected ear. Smaller tilts (approximately 7 degrees) of the SVV occurred in patients with spontaneous peripheral vestibular diseases. This shift in SVV disappeared within weeks to months, similar to the spontaneous nystagmus. After stapes surgery slight deviations of the SVV towards the unoperated ear were seen in about 20% of the patients, indicating a slight irritation of the otolith organs. Assessed in an upright position, the SVV thus may be regarded as reflecting tonic otolithic input differences between the two ears. Asymmetries in the shifts of the SVV induced by roll tilts of the gravito-inertial vector by eccentric rotations of the subject have been proposed as a test for otolithic sensitivity. In our studies such asymmetries in the shifts of the SVV could not be induced by 26 degrees or 90 degrees roll tilts of subjects towards the affected or healthy ears. A simple clinical test to reveal unilateral otolithic sensitivity (comparable to an otolithic "caloric test") thus still has to be found.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Böhmer. 1997. [Evaluating otolith function with subjective visual vertical discrimination].. https://doi.org/10.1007/s001060050127

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

LED-generated multifocal ERG on- and off-responses in complete congenital stationary night blindness -- a case report.

We report on the application of a light emitting diode (LED) screen to elicit multifocal ERG on- and off-responses in a patient presenting with the complete type of congenital stationary night blindness (cCSNB): A 63-years old woman was diagnosed with cCSNB by means of standard ERG procedures and dark adaptometry. To confirm this diagnosis and to investigate topographical differences of on- and off-responses a multifocal approach employing long-duration stimuli was added. Results of mfERG-testing were averaged in three groups (a central area of 7.5 degrees , a ring area of 7.5-21.9 degrees and a peripheral ring of 21.9-31.1 degrees ). When compared to normal controls (n = 4) on-responses (P1-amplitudes) were severely reduced symmetrically at all eccentricities, while off-responses showed no reduction resulting in an increased off/on-ratio. Furthermore on-latencies of P1 were delayed symmetrically at all eccentricities, whereas off-latencies were normal. To our knowledge this is the first report of multifocal on- and off-responses in a CSNB-patient. Stimulus-generation with a LED-screen provides the advantage of a stable luminance during the long-duration on-phase.

Dark Adaptation↗

Is the spectacle lens jack-in-the-box phenomenon really due to the lenses?

The calculation of the extent of the ring scotoma around positive lenses, as conventionally taught to students of clinical optics, indicates that the scotoma is of a significant size. Using knife-edge lenses this study shows that the calculations are invalid due to the finite size of the eye's entrance pupil and in many instances the scotoma is shown not to exist. The effect noticed in clinical practice is probably largely due to the frame and the edging techniques used which add to the refractive scotoma which is present with high powered lenses, large apertures and/or small pupil sizes.

Dark Adaptation↗