Abstract

State-of-the-art subretinal surgery involves a standard three-port pars plana entry, followed by an iatrogenic retinotomy to access the subretinal space. Subretinal manipulations through a small retinotomy are made possible by specially designed instruments. As the surgeon looks through the vitreous cavity, all subretinal maneuvers are obscured by the overlying retina. Consequently, the surgeon is operating 'blindly' and has to rely on 'feeling' rather than direct visualization. Micro-endoscopic viewing systems are the ideal solution for visualization during subretinal surgery. Until now, such endoscopes were either too large for intraocular use or lacked sufficient resolution, especially at a short working distance. Recently, a gradient index (GRIN) endoscope was developed (Insight Instruments, Inc., Lake Mary, Fla., USA) combining a small diameter (0.89 mm, 20 gauge) and incorporating excellent optical resolution, even at extremely close working distances. After ballooning a limited part of the retina without creating a retinal hole, the 20-gauge GRIN endoscope can be introduced into the subretinal space through the sclera and choroid, posterior to the pars plana. Surgical instruments can then be introduced into the subretinal space through a second neighboring sclerotomy. Thus, subretinal surgery can be performed under direct endoscopic control. As a result of direct visualization, the surgeon may perform certain surgical procedures with greater accuracy, i.e., subretinal neovascular membranes may be dissected meticulously from the neurosensory retina and retinal pigment epithelium, minimizing damage to both structures. The feeding choroidal vessel can be identified and directly coagulated, which is usually very difficult during conventional subretinal surgery. Endoscopic subretinal surgery is thus a significant improvement over conventional methods, avoiding the need for a retinotomy and increasing the safety and facility of the surgery itself.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F H Koch, K P Luloh, A J Augustin, M S el Agha, H Guembel, C Ohrloff, W S Grizzard, M E Hammer, S Sinclair. 1997. Subretinal microsurgery with gradient index endoscopes.. https://doi.org/10.1159/000310809

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Training with simulation improves residents' endovascular procedure skills.

BACKGROUND: Endovascular procedure simulators are now commercially available and in use for physician training. The purpose of this study was to evaluate the role of simulation-based training in vascular surgery residencies. METHODS: Residents from vascular surgery programs in a five-state area were invited to participate in a series of 2-day endovascular training programs that used a high-fidelity endovascular procedure simulator (SimSuite; Medical Simulation Corporation, Denver, Colo), didactic instruction, computer-based training, and tabletop procedure demonstrations. The curriculum covered arteriography and intervention for treatment of aortoiliac, renal, and carotid artery disease. Nine residents participated, with one to three per training session. Each completed an average of 9.5 simulated endovascular cases. Performance on a standardized TransAtlantic Inter-Society Consensus B iliac angioplasty/stenting case was used to assess endovascular skills and knowledge at the beginning of the training program, and this was repeated at the completion of the training. Performance metrics were measured by the simulator, faculty observed trainees' performance of simulated cases, and trainees provided their evaluations of the usefulness of the simulation experiences. RESULTS: Endovascular procedural skills on the standardized iliac intervention case improved after completion of the training program. Compared with performance early on day 1, performance improved (P < or = .05; paired t test): total procedure time decreased 54%, volume of contrast decreased 44%, and fluoroscopy time decreased 48% (mean change from baseline). Selection of angioplasty balloon catheters and stents was improved, and the average number of catheters used and stents deployed decreased, although this did not reach statistical significance. Faculty observation allowed identification of shortcomings of knowledge and skills, including common problems with selection of catheter, balloon, and stent sizes; correct positioning of the sheath; and intraprocedural monitoring. Postcourse evaluations indicated support for the use of simulation in vascular surgery residents' endovascular training. CONCLUSIONS: Training with a simulator, incorporated into an individual or small group learning session, offers a means to learn and realistically practice endovascular procedures without direct risk to patients, with measurable improvements in key performance metrics. How simulation training affects subsequent clinical performance has yet to be established.

Endoscopy↗

Intraoperative surgical navigation for endoscopic sinus surgery: rationale and indications.

PURPOSE OF REVIEW: The present review discusses the rationale and indications for image-guided surgery through a critical discussion of registration concepts as well as clinical reports. RECENT FINDINGS: The surgical navigation accuracy achieved by commercially available image-guided surgery systems is best reported as target registration error. Clinically achievable target registration error is probably in the 1.5-2.0 mm range. Dry lab studies of registration serve to highlight the principles of registration, the process through which image-guided surgery systems calculate the one-to-one mapping relationship between the preoperative imaging data and the intraoperative surgical volume. Reports on image-guided surgery have highlighted its usefulness in primary and revision endoscopic sinus surgery, osteoplastic frontal sinusotomy, transsphenoidal hypophysectomy, endoscopic cerebrospinal fluid leak repair and endoscopic pterygomaxillary fossa biopsy. Both three-dimensional computed tomography angiography and computed tomography-magnetic resonance fusion images have been incorporated into IGS for advanced minimally invasive endoscopic skull base procedures. The American Academy of Otolaryngology-Head and Neck Surgery policy statement accurately summarizes the current consensus for image-guided surgery applications. SUMMARY: Image-guided surgery has emerged as an important technology, which both general otolaryngologists and subspecialty rhinologists can employ for a wide variety of procedures.

Endoscopy↗