Search PubMed⌕ Search

PubMed · 9282276

Body composition at the bedside.

Abstract

OBJECTIVE: To evaluate the use of an inexpensive hand-held bioelectric impedance analysis machine which measures lean body mass, by technical comparisons against standard instruments and techniques (an in-house bioelectric impedance machine and dual energy X-ray absorptiometry), and by performing body composition analyses in groups of potentially malnourished patients. DESIGN: Prospective simultaneous comparison of measurements made by the hand-held and in-house bioelectric analysis machines and dual energy x-ray absorptiometry. SETTING: Medical Physics Department and Gastrointestinal Unit in a university teaching hospital. SUBJECTS/METHODS: One hundred and sixty subjects were recruited into the study. Data from 58 adolescent and 14 adult volunteers and from 42 adult patients were used for technical comparisons (n = 114). Body composition information was evaluated (n = 102) for 60 adult volunteers and 42 patients (17 with eating disorders, 7 with chronic alcoholic pancreatitis and 18 with inflammatory bowel disease). OUTCOME MEASURES: Estimation of bias, limits of agreement and correlations on data from the three machines. Relationships between percentage body mass as lean, absolute weights and body mass index, in the adult subjects. RESULTS: Both resistance and calculated impedance measured by the hand-held machine significantly correlated with the impedance measured by the in-house machine (r = 0.996; P < 0.0001). An estimation of the level of agreement in percentage lean measurement between dual energy x-ray absorptiometry and hand-held bioelectrical impedance analysis machine by the Bland and Altman method showed a bias of -0.07% and satisfactory limits of agreement from -7.97% to 7.76%. Body mass index was similar in the groups of healthy men and women, but proportion of weight as lean was significantly higher in men than women. In underweight patients with eating disorders, the ratio of lean to fat varied widely; in inflammatory bowel disease patients, proportions of lean and fat were similar to controls; however patients with alcoholic pancreatitis had values for body mass index similar to controls, but had significantly lower proportion of their body weight as lean (P < 0.05). CONCLUSION: In non-obese and thin adults, an accurate two-compartment (lean, fat) measurement of body composition can be made in 10 min by using an inexpensive, hand-held, bioelectric impedance analysis machine.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Ghosh, D Meister, S Cowen, W J Hannan, A Ferguson. 1997. Body composition at the bedside.. https://doi.org/10.1097/00042737-199708000-00009

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗