Virtual extracorporeal circulation process.

Abstract

Virtual instruments for an extracorporeal circulation (ECC) process were developed to simulate the reactions of a patient to different artificial perfusion conditions. The computer simulation of the patient takes into account the hydraulic, volume, thermal and biochemical phenomena and their interaction with the devices involved in ECC (cannulae dimensions, oxygenator and filter types, pulsatile or continuous pump and thermal exchangers). On the basis of the patient's initialisation data (height, weight, Ht) and perfusion variables (pump flow rate, water temperature, gas flow rate and composition) imposed by the operator, the virtual ECC monitors simulated arterial and venous pressure tracings in real time, along with arterial and venous flow rate tracings, urine production tracing and temperature levels. Oxyhemoglobin arterial and venous blood saturation together with other related variables (pO2, pCO2, pH, HCO3 are also monitored. A drug model which allows the simulation of the effect of vasodilator and diuretic drugs is also implemented. Alarms are provided in order to check which variables (pressure, saturation, pH, urine flow) are out of the expected ranges during the ECC simulation. Consequently the possibility of modifying the control parameters of the virtual devices of the ECC in run-time mode offers an interaction mode between the operator and the virtual environment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Boschetti, F M Montevecchi, R Fumero. 1997. Virtual extracorporeal circulation process.. https://pubmed.ncbi.nlm.nih.gov/9259211/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Respiratory status of infants with esophageal atresia.

In infants with esophageal atresia (EA), lung opacities on a chest radiograph (CXR) are usually considered the cause of respiratory distress (RD). However, in some instances signs of RD and CXR changes show no correlation. The aim of this study was to investigate the pathogenesis of RD in EA patients with a normal CXR. In 41 infants with EA, CXR findings were correlated with clinical manifestations and blood-gas analysis data. The degree of abnormal gas exchange was quantitated by the arterial/alveolar oxygen tension ratio (a-ARO2). Of the 41 infants, 39(95%) presented with RD. No lung opacities were found in 130 of 294 CXRs examined (44%). An a-ARO2 below 0.75 (lower limit of normal) was calculated in 215 of 247 arterial blood samples analyzed (87%). When a temporal correlation was established, RD with a clear CXR was characterized by signs of extra- and intrathoracic airway obstruction, often associated with an a-ARO2 below 0.75. The degree of hypoxemia was greater than the degree of hypercapnia. We conclude that in infants with EA, RD with a clear CXR is related to both tracheomalacia and upper-airway obstruction that may cause miliary atelectasis not detected by conventional CXR with intrapulmonary shunting and hypoxemia.

Blood Gas Analysis↗

New QC process validates new blood gas technology at each measurement.

NPT7, developed by Radiometer Medical, Copenhagen, Denmark, is a blood gas analyzer optimized for the near-patient setting. The analyzer is based on dry, optical technologies and single-use cuvettes. The quality of each individual measurement is validated by a new approach to internal quality control, which has been named QualityGuard. This paper provides an overview of QualityGuard and, using the pCO2 measurement as an example, describes how the different elements of QualityGuard manages the quality control of the NPT7 itself, and of the quality of a measurement.

Blood Gas Analysis↗

Blood gas analysis: POCT versus central laboratory on samples sent by a pneumatic tube system.

BACKGROUND: We aimed to compare the results of blood gas analyses, performed at point-of-care and in the central laboratory (CL), on samples sent via a pneumatic tube system (PTS). METHOD: Specimens from two locations (lung function laboratory (LFL) and pneumology wards) were first analysed locally and then sent to the CL via PTS. RESULTS: While none of the blood gas samples from the LFL had air bubbles, 21 samples from the wards (n=31) had air bubbles in them. The mean time difference between the first (POCT) and the second (CL) determinations from LFL was 13.3+/-5.4 min (n=27) and from the wards 20.2+/-11 min. For pO2 the differences between LFL and CL results, for patients undergoing a 100% O2 test, were unacceptably large. For pO2 range 41-407 mm Hg, the difference was -2.4+/-3.2 (n=25). For the samples from the wards, the difference in pO2 between ward (range 37-183 mm Hg) and CL was -13+/-18 mm Hg. CONCLUSION: Irrespective of air bubbles, the transport by PTS has very little or no effect on pH and pCO2. If air bubbles cannot be excluded with certainty, PTS is not an appropriate transport medium for measurement of pO2 on blood gas samples.

Blood Gas Analysis↗