Search PubMed⌕ Search

PubMed · 9255562

Mini- and microsatellites.

Abstract

While the faithful transmission of genetic information requires a fidelity and stability of DNA that is involved in translation into proteins, it has become evident that a large part of noncoding DNA is organized in repeated sequences, which often exhibit a pronounced instability and dynamics. This applies both to longer repeated sequences, minisatellites (about 10-100 base pairs), and microsatellites (mostly 2-4 base pairs). Although these satellite DNAs are abundantly distributed in all kinds of organisms, no clear function has been discerned for them. However, extension of trinucleotide microsatellite sequences has been associated with several severe human disorders, such as Fragile X syndrome and Huntington's disease. Rare alleles of a minisatellite sequence have been reported to be associated with the ras oncogene leading to an increased risk for several human cancers. A dynamic behavior of repeated DNA sequences also applies to telomeres, constituting the ends of the chromosomes. Repeated DNA sequences protect the chromosome ends from losing coding sequences at cell divisions. The telomeres are maintained by the enzyme telomerase. Somatic cells, however, lose telomerase function and gradually die. Cancer cells have activated telomerase and therefore they acquire immortality.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Ramel. 1997. Mini- and microsatellites.. https://doi.org/10.1289/ehp.97105s4781

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Run-specific limits of detection and quantitation for STR-based DNA testing.

STR-based DNA profiling is an exceptionally sensitive analytical technique that is often used to obtain results at the very limits of its sensitivity. The challenge of reliably distinguishing between signal and noise in such situations is one that has been rigorously addressed in numerous other analytical disciplines. However, an inability to determine accurately the height of electropherogram baselines has caused forensic DNA profiling laboratories to utilize alternative approaches. Minimum thresholds established during laboratory validation studies have become the de facto standard for distinguishing between reliable signal and noise/technical artifacts. These minimum peak height thresholds generally fail to consider variability in the sensitivity of instruments, reagents, and the skill of human analysts involved in the DNA profiling process over the course of time. Software (BatchExtract) made publicly available by the National Center for Biotechnology Information now provides an alternative means of establishing limits of detection and quantitation that is more consistent with those used in other analytical disciplines. We have used that software to determine the height of each data collection point for each dye along a control sample's electropherogram trace. These values were then used to determine a limit of detection (the average amount of background noise plus three standard deviations) and a limit of quantitation (the average amount of background noise plus 10 standard deviations) for each control sample. Analyses of the electropherogram data associated with the positive, negative, and reagent blank controls included in 50 different capillary electrophoresis runs validate that this approach could be used to determine run-specific thresholds objectively for use in forensic DNA casework.

DNA Fingerprinting↗