Search PubMed⌕ Search

PubMed · 9138063

Hydroxyapatite-coating on titanium arc sprayed titanium implants.

Abstract

We developed a new titanium spray technique using an inert gas shielded arc spray (titanium arc spray). Hydroxyapatite (HA)-coating can be applied to the implant without any surface pore obstruction after the rough surface is made by this technique. Scanning electron microscopy (SEM) of various porous implant surfaces after HA-coating revealed that the bead and fiber metal-coated implants had either a pore obstruction or an uneven HA-coating. On the other hand, the titanium arc sprayed implant demonstrated an even HA-coating all the way to the bottom of the surface pore. In the first set of animal experiments (Exp. 1), the interfacial shear strength to bone of four kinds of cylindrical Ti-6A1-4V (Ti) implants were compared using a canine transcortical push-out model 4 and 12 weeks after implantation. The implant surfaces were roughened by titanium arc spray (group A-C) and sand blasting (group D) to four different degrees (roughness average, Ra = group A: 56.1, B: 44.9, C: 28.3, D: 3.7 microns). The interfacial shear strength increased in a surface roughness-dependent manner at both time periods. However, the roughest implants (group A) showed some failed regions in the sprayed layers after pushout test. In the second set of animal experiments (Exp. 2), four kinds of Ti implants; HA-coated smooth Ti (sHA) with Ra of 3.4 microns, bead-coated Ti (Beads), titanium arc sprayed Ti (Ti-spray) with Ra of 38.1 microns and HA-coated Ti-spray (HA + Ti-spray) with Ra of 28.3 microns were compared using the same model as that in Exp. 1. The interfacial shear strength of HA + Ti-spray was significantly greater than that of sHA and Beads at both time periods, and that of Ti-spray at 4 weeks. Although a histological examination revealed that HA-coating enhanced bone ingrowth, sHA showed the lowest shear strength at both time periods. SEM after pushout test showed that sHA consistently demonstrated some regional failure at the HA-implant substrate interface. HA + Ti-spray had many failed regions either at the HA-bone interface or within the bone tissue rather than at the HA-implant substrate interface. These results suggested that the HA-coated smooth surfaced implants had a mechanical weakness at the HA-substrate interface. Therefore, HA should be coated on the rough surfaced implants to avoid a detachment of the HA-coating layer from the substrate and thus obtain a mechanical anchoring strength to bone. HA-coating on this new type of surface morphology may thus lead to a solution to the problems of conventional HA-coated and porous-coated implants.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Nakashima, K Hayashi, T Inadome, K Uenoyama, T Hara, T Kanemaru, Y Sugioka, I Noda. 1997-06-05. Hydroxyapatite-coating on titanium arc sprayed titanium implants.. https://doi.org/10.1002/(sici)1097-4636(19970605)35%3A3%3C287%3A%3Aaid-jbm3%3E3.0.co%3B2-d

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Osseointegration of hydroxyapatite-coated and noncoated Ti6Al4V implants in the presence of local infection: a comparative histomorphometrical study in rabbits.

A study was designed to investigate the osseointegration of titanium implants, either noncoated or coated with hydroxyapatite (HA), into rabbit tibiae in the presence of local infection compared with osseointegration in the absence of local infection. HA-coated or noncoated Ti cylinders were implanted into both tibiae of 32 rabbits (New Zealand Whites). Before implantation the left tibia was contaminated with different quantities of Staphylococcus aureus (10(2)-10(5) CFU). Four weeks after surgery the tibiae were explanted and prepared for microbiological and histomorphometrical examination. Histomorphometrical data, as a representation of implant fixation, were obtained by measuring the percentage of bone around the implants (within a radius of 1 mm from the outer diameter of the implants) and the percentage of the circumference of the implant that was in direct contact with bone. Histomorphometry revealed, in particular for the HA implants, a relationship between the inoculum concentration and/or the presence or absence of infection with the bone contact at the distal implant side. This confirms a relationship between peri-implant infection and bone contact or remodeling. HA-coated implants developed, in the presence of bacteria, more easily a more severe infection than noncoated Ti implants, and we show in the present study that local infection will influence histomorphometrical parameters (bone-implant contact) that determine implant fixation. Precautions to prevent contamination (asepsis) and/or infection (perioperative antibiotics) are even more important for the highly biocompatible HA-coated implant.

Alloys↗

Proliferation and differentiation of rat calvarial osteoblasts on type I collagen-coated titanium alloy.

Several attempts have been made to improve osseointegration of titanium alloy as an implant material by modification of its surface. In the present study, proliferation, differentiation, and mineralization of osteoblasts on type I collagen-coated Ti6Al4V were investigated. The activity of alkaline phosphatase and the accumulation of calcium by osteoblasts grown on titanium alloy were significantly higher compared to cells grown on polystyrene. Precoating of the implant surface with type I collagen did not extensively affect proliferation, the activity of alkaline phosphatase, collagen synthesis, calcium accumulation, or the mRNA levels for collagen I alpha1, osteopontin, osteocalcin, MMP-2, and TIMP-2. Maximum collagen synthesis by osteoblasts was observed at day 4 of culture independent of the type of implant material. The specific activity of alkaline phosphatase reached its maximum at day 18 of culture. Accumulation of calcium and elevated mRNA levels for osteocalcin were found at day 22. These results indicate that collagen-coating alone is not sufficient to accelerate differentiation of rat calvarial osteoblasts on Ti6Al4V.

Alloys↗

On carbide dissolution in an as-cast ASTM F-75 alloy.

The solution treatment of an as-cast ASTM F-75 alloy was investigated. Microstructural evolution was followed during thermal processing, in particular with regard to the content and type of carbides formed. To evidence any probable carbide transformations occurring during the heating stage, as well as to clarify their effect on the carbide dissolution kinetics, three heating rates were studied. Image analysis and scanning electron microscopy techniques were used for microstructural characterization. For the identification of precipitates, these were electrolytically extracted from the matrix and then analyzed by X-ray diffraction. It was found that the precipitates in the as-cast alloy were constituted by both a M(23)C(6) carbide and a sigma intermetallic phase. The M(23)C(6) carbide was the only phase identified in solution-treated specimens, regardless of the heating rate employed, which indicated that this carbide dissolved directly into the matrix without being transformed first into an M(6)C carbide, as reported in the literature. It was found that the kinetics of dissolution for the M(23)C(6) carbide decreased progressively during the solution treatment, and that it was sensitive to the heating rate, decreasing whenever the latter was decreased. Because the M(23)C(6) carbide was not observed to suffer a phase transformation prior to its dissolution into the matrix, the effect of the heating rate was associated to the morphological change occurred as the specimens were heated. The occurrence of the observed phases was analyzed with the aid of phase diagrams computed for the system Co-Cr-Mo-C.

Alloys↗