Search PubMedSearch

PubMed · 913623

Studies on bone ion exchanges using multiple-tracer indicator-dilution techniques.

Abstract

Free diffusion appears to be the principal mechanism for movement of ions, known to concentrate in bone, across the capillaries of bone. The interstitial fluid space appears large enough to allow for determination of instantaneous fractional escape by the indicator-dilution method. The mechanism by which large molecules, such as the diphosphonate 99mTc-labeled EHDP or 99mTc-labeled pyrophosphate, pass through capillaries in bone is by passive diffusion. These molecules are larger than 85Sr and their lower extraction rate is presumably due to the effect of their sizes on passage through transcapillary clefts. A corollary of these studies might be that if transcapillary exchange is passive, then partition of anions and cations likely lies beyond the capillary and therefore is controlled by osteal cellular processes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P J Kelly, J B Bassingthwaighte. 1977. Studies on bone ion exchanges using multiple-tracer indicator-dilution techniques.. https://pubmed.ncbi.nlm.nih.gov/913623/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

In vitro evaluation of a new lithium dilution method of measuring cardiac output and shunt fraction in patients undergoing venovenous extracorporeal membrane oxygenation.

OBJECTIVE: To evaluate, in vitro, a method of measuring cardiac output and shunt fraction during venovenous extracorporeal membrane oxygenation (ECMO). DESIGN: Experimental study using an in vitro model. SETTING: A teaching hospital. MODEL: An ECMO circuit was set up in parallel with a patient circuit consisting of tubing through which saline was circulated from a 50-L reservoir by a pump which was set at 3 L/min to represent cardiac output. A second pump in the ECMO circuit drew saline from the patient circuit and passed it through a membrane oxygenator. The flow from the membrane oxygenator either returned directly to the patient circuit or was diverted, via a third pump, back into the ECMO circuit, thereby producing a shunt. INTERVENTIONS: By adjusting the flow rates of the second (ECMO) and third (shunt) pumps, three shunt fractions of 12%, 25%, and 50% were produced at three different ECMO flow rates. Lithium chloride (0.15 mmol) was injected just downstream of the membrane oxygenator; the lithium ion concentration-time curves were recorded simultaneously in the flow returning to the saline reservoir and in the flow just upstream of the membrane oxygenator using lithium selective electrodes. MEASUREMENTS AND MAIN RESULTS: Nine pairs of curves were recorded, one pair for each combination of ECMO and shunt flow rates. Analysis of these curves allowed shunt flow and "cardiac output" to be calculated and compared with the flow rates delivered by the pumps. Mean "cardiac output" derived from the lithium dilution curves was 2.98 +/- 0.18 (SD) L/min, compared with a delivered pump flow of 3 L/min. Measured shunt flow = 0.008 + 1.09 x actual shunt flow (R = 0.997). CONCLUSIONS: This method would allow cardiac output and shunt flow to be measured in patients undergoing venovenous ECMO. It could result in better patient management and improved cannula design.

Blood Flow Velocity

Assessment of left internal mammary artery grafts using dipyridamole Doppler echocardiography.

Color Doppler echocardiography of the left mammary artery was combined with dipyridamole testing in order to assess the presence of significant (>70%) graft stenosis in 87 patients with a mammary artery graft to the left anterior descending coronary artery presenting with chest pain. Occluded grafts are detected by absent diastolic flow velocities at baseline, whereas the response of the diastolic flow velocity to dipyridamole distinguishes patients with critical versus noncritical stenosis of a patent graft.

Blood Flow Velocity