Abstract
Results were evaluated in 81 patients with suspected acute aortic dissection who were examined on a fast CT system capable of a 1 s data acquisition time. 17 patients had Type A and nine had Type B dissections. Radiological assessment provided 78 confident reports and expressed some uncertainty about the diagnosis in three patients. Overall sensitivity for aortic dissection was 96.2% and specificity was 96.4%. When 78 confident reports alone were considered, both sensitivity and specificity reached 100%. Reconstruction of data at 100 ms intervals allowed discrimination between artefacts in the ascending aorta and Type A dissections. CT can often be used as the single investigation prior to surgery for acute Type A dissections.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
J H Small, A K Dixon, R A Coulden, C D Flower, B A Housden. 1996. Fast CT for aortic dissection.. https://doi.org/10.1259/0007-1285-69-826-900