[Continuous hemofiltration. Development of an experimental model].

Abstract

OBJECTIVE: Continuous hemofiltration is an extracorporeal technique used to eliminate water and solutes by convective transport through a hemofilter. The aim of this study was to develop an experimental model of arterio-venous and veno-venous continuous hemofiltration in order to gain experience before its clinical application in human neonates. MATERIALS AND METHODS: Twelve white New Zealand adult rabbits were anesthetized, tracheotomized and connected to a continuous flow neonatal ventilator. Continuous arterio-venous hemofiltration (n = 6) was performed via catheters placed in the carotid artery and jugular vein and veno-venous hemofiltration (n = 6) by a double-lumen catheter located in the inferior vena cava. Heart rate, arterial pressure, pH and blood gases, and the volume of ultra-filtrate were monitored and recorded for a three hour period. RESULTS: In both groups a high rate of ultrafiltration was achieved. The volume of ultrafiltration decreased somewhat during the second hour and remained stable thereafter. No hemodynamic changes were detected. CONCLUSIONS: The development of an experimental model for continuous arterio-venous and veno-venous hemofiltration in rabbits, facilitated the implantation of these techniques in human neonates. The model may be used to train the staff of the Neonatal Intensive Care Unit and to eliminate difficulties with vascular access and the care of extracorporeal lines.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Gastiasoro Cuesta, F J Alvarez Díaz, A Arnaiz Renedo, A Palmero Sánchez, L Alfonso Sánchez, A Valls i Soler. 1996. [Continuous hemofiltration. Development of an experimental model].. https://pubmed.ncbi.nlm.nih.gov/9036784/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗