Reticulocyte analysis using flow cytometry.

Abstract

Automation of the reticulocyte count by means of flow cytometry has considerably improved the quality of this investigation. This article deals firstly with the reasons for the poor performance of the microscopic technique and with the physiological principles underlying identification and classification of reticulocytes using RNA labeling. It then outlines the automated methods currently on the market, which can be classified in three categories: a) "general-purpose" cytofluorometers, which in clinical laboratories usually deal with lymphocyte immunophenotyping; b) the only commercially available cytofluorometer dedicated to the reticulocyte count; this automat has the advantage of requiring no human intervention as it merely needs to be fed with samples; c) hematology analyzers with specific modules for automatic counting of reticulocytes previously incubated with a non-fluorescent dye. Of the various fluorescent markers available, thiazole orange, DEQTC iodide and auramine are most often used for this basic hematology test. The quality of the count, the availability of new reticulocyte indices (maturation index, percentage of young reticulocytes) and rapidity of the count give this test renewed value in the practical approach to the diagnosis of anemia, and also open new perspectives in the surveillance of aplastic anemia after chemotherapy or bone marrow grafting.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J X Corberand. 1996. Reticulocyte analysis using flow cytometry.. https://doi.org/10.1007/s00282-996-0487-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Regulation of protein synthesis by the heme-regulated eIF2alpha kinase: relevance to anemias.

During erythroid differentiation and maturation, it is critical that the 3 components of hemoglobin, alpha-globin, beta-globin, and heme, are made in proper stoichiometry to form stable hemoglobin. Heme-regulated translation mediated by the heme-regulated inhibitor kinase (HRI) provides one major mechanism that ensures balanced synthesis of globins and heme. HRI phosphorylates the alpha-subunit of eukaryotic translational initiation factor 2 (eLF2alpha) in heme deficiency, thereby inhibiting protein synthesis globally. In this manner, HRI serves as a feedback inhibitor of globin synthesis by sensing the intracellular concentration of heme through its heme-binding domains. HRI is essential not only for the translational regulation of globins, but also for the survival of erythroid precursors in iron deficiency. Recently, the protective function of HRI has also been demonstrated in murine models of erythropoietic protoporphyria and beta-thalassemia. In these 3 anemias, HRI is essential in determining red blood cell size, number, and hemoglobin content per cell. Translational regulation by HRI is critical to reduce excess synthesis of globin proteins or heme under nonoptimal disease states, and thus reduces the severity of these diseases. The protective role of HRI may be more common among red cell disorders.

Anemia↗

A test for publication bias in meta-analysis with sparse binary data.

A new test for the detection of publication bias in meta-analysis with sparse binary data is proposed. The test statistic is based on observed and expected cell frequencies, and the variance of the observed cell frequencies. These quantities are utilized in a rank correlation test. Type I error rate and power of the test are evaluated in simulations; results are compared to those of two other commonly used test procedures. Sample sizes were generated according to findings in a survey of eight German medical journals. Simulation results indicate that, in contrast to existing test procedures, the new test holds the prescribed significance level when data are sparse. However, the power of all tests is low in many situations of practical importance.

Anemia↗

Center effects in anemia management of dialysis patients.

This study set out to determine whether there is a center effect on anemia management in hemodialysis patients. The US Renal Data System and Medicare standard analysis files were analyzed. Between-center variation and within-facility correlations in hematocrit values were examined in two separate data sets (years 2000 and 2001) and compared with simulated samples that were composed of random values that assumed no center effect. Mixed-effect models were used to adjust for multiple factors and quantify the within-facility correlation in hematocrit values. Expected hematocrit values were compared in patients who underwent dialysis at poor and superior performing facilities with fixed characteristics including epoetin alpha dosing. There was a wider center variation in hematocrit for the actual versus simulated data and a coefficient of variation of 4.1% for the former versus 1.7% for the latter, in both years. The within-facility correlation for hematocrit was 0.053 (95% confidence interval 0.050 to 0.056; P < 0.001) in 2000 with similar values in 2001 but no within-facility correlation in the simulated data. The impact of these findings was demonstrated with a difference in expected hematocrit for a patient who was treated with fixed-dosage epoetin alpha in the poorest versus best performing units (mean difference in expected hematocrit 3.06; 95% confidence interval 3.03 to 3.09; P < 0.001). Key attributes of a center effect on anemia management in hemodialysis have been identified. The presence of a center effect suggests that there are facility-specific processes that influence performance in dialysis anemia management and are independent of commonly titrated inputs, such as dosing of erythropoietic agents.

Anemia↗