PAPNET Testing System. Technical update.

Abstract

OBJECTIVE: To extensively test the functional integrity of the PAPNET Testing System, a computer-assisted cervical smear rescreening device, to ensure performance and reliability. STUDY DESIGN: Various system and subsystem testing methodologies were used to verify that the PAPNET Scanning Station performed according to specifications. Using synthetic and biologic slides, proper operation of the system in its intended use environment was verified. An automated system test was employed to demonstrate the ability of the system to detect cytologic abnormality. Several tests were performed throughout the production process and normal operation to ensure subsystem operations. RESULTS: The testing methodologies were shown to provide accurate measurements of scanning performance. CONCLUSION: Methodical testing and implementation of technologic enhancements ensure system performance and reliability. When used with microscopy, PAPNET testing provides the means to improve the accuracy of cervical cytology.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T J Denaro, J M Herriman, O Shapira. PAPNET Testing System. Technical update.. https://doi.org/10.1159/000332307

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Automated analysis of mitochondrial enzymes in cultured skin fibroblasts.

We report automated methods for assaying the activities of the mitochondrial respiratory chain enzyme cytochrome c oxidase (COX), the matrix enzyme citrate synthase (CS), and the cytoplasmic enzyme lactate dehydrogenase (LDH) on a random access analyzer, the Roche Mira S. COX activity was assayed by measuring the initial rate of oxidation of reduced cytochrome c. The CS assay was based on the reaction of this enzyme with oxaloacetate and acetyl-CoA to produce CoASH, which further reacts with dithionitrobenzoic acid producing a free thionitrobenzoate ion. LDH activity was assayed by measuring the reduction of nicotinamide adenine dinucleotide during the oxidation of lactate to pyruvate. Precision of the COX assay was 2. 3%, CS assay 0.7%, and LDH 5.6%. These automated methods were faster by as much as 80%, cheaper by 50%, and used less than half the sample material needed for traditional manual methods. While these assays are often performed by specialized laboratories using dedicated staff, the automated methods presented here are easily performed by staff trained in the regular diagnostic laboratory.

Automation