Search PubMed⌕ Search

PubMed · 8969981

Uniform matrix stability study designs.

Abstract

Uniform matrix designs for drug stability studies are introduced and compared to standard matrix designs. Comparisons are made on the basis of design moment, D-efficiency, uncertainty, G-efficiency, and statistical power. It is shown that uniform matrix designs provide superior statistical properties with the same or fewer design points than standard matrix designs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J R Murphy. 1996. Uniform matrix stability study designs.. https://doi.org/10.1080/10543409608835157

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimization of a thermally reversible W/O/W multiple emulsion for shear-induced drug release.

PURPOSE: The present work aimed at improvement of the formulation of a previously developed thermo-reversible W/O/W multiple emulsion by increasing the emulsion stability and reaching a higher fraction of an encapsulated drug released under shear. The emulsion was based on high molecular weight graft-copolymers of poly(acrylic acid) and Pluronic F127 as stabilizing agents. METHODS: Once a stable W/O/W thermo-reversible multiple emulsion was obtained via a fine-tuning of the formulation, rheological, granulometric and conductometric tests were performed to assess the thermo-reversible behavior and the fragmentation-release characteristics of the new W/O/W multiple emulsion. RESULTS: The emulsion exhibited a 10(3) fold increase in viscosity over a range of temperatures from 20 to 40 degrees C. At moderate shearing, a complete release of the marker encapsulated in the internal aqueous phase was observed (99.6%) at 35 degrees C, whereas only 30% was released at 20 degrees C. Under similar conditions at 35 degrees C, slightly more than 50% was released for the initial formula. CONCLUSION: Additionally, the ease of fabrication of the thermo-reversible W/O/W multiple emulsion combined with the complete release under shear at body temperature and the superior emulsion stability suggest numerous applications in the controlled release of drugs.

Chemistry, Pharmaceutical↗

Non-degradable microparticles containing a hydrophilic and/or a lipophilic drug: preparation, characterization and drug release modeling.

Non-degradable microparticles based on ammonio methacrylate copolymers (Eudragit RS:RL 4:1 blends) containing the hydrophilic drug propranolol HCl and/or the lipophilic drug nifedipine were prepared with an oil-in-water (O/W) and a water-in-oil-in-water (W/O/W) solvent evaporation technique. Both drugs were successfully incorporated separately as well as simultaneously. In all cases, the resulting release rate(s) of the drug(s) was/were found to be controlled over periods of at least 8 h. To elucidate the underlying mass transport mechanisms, the microparticles were thoroughly characterized by X-ray powder diffractometry, differential scanning calorimetry, particle size analysis, and determination of the actual drug loading(s). Analytical solutions of Fick's second law of diffusion considering non-steady state conditions were used to describe the release of propranolol HCl. Interestingly, the resistance for drug release within the unstirred liquid boundary layers on the surfaces of the microparticles was found to be negligible compared to the diffusional resistance within the polymeric devices. Importantly, the mathematical theories could be used to normalize the experimentally determined in vitro drug release with respect to the microparticle size. Thus, the effect of the type of preparation method (O/W vs. W/O/W) and device composition (polymer blend plus one drug only vs. polymer blend plus drug combination) on the diffusional resistance within the microparticles could be studied. In addition, further insight into the occurring mass transport processes was gained. For example, the time-dependent evolution of the drug concentration profiles within the microparticles upon exposure to the release medium could be calculated. An interesting practical application of the mathematical theories is the possibility to predict the effect of different formulation parameters on the resulting drug release patterns, e.g. the effect of the microparticle size.

Chemistry, Pharmaceutical↗

Comparative study of the lubricant performance of Compritol HD5 ATO and Compritol 888 ATO: effect of polyethylene glycol behenate on lubricant capacity.

The aim of this paper is to study the lubricant capacity of Compritol HD5 ATO, a glyceryl and polyethylene glycol dibehenate, obtained by atomization. This material is compared to Compritol 888 ATO, constituted only by glyceryl dibehenate. First, this study verifies that Compritol HD5 ATO and Compritol 888 ATO present the same granular characteristics and that their mixes with Lactopress present no structural differences. Secondly, in term of compressibility and cohesiveness, the use of Compritol 888 ATO or Compritol HD5 ATO with Lactopress does not involve any significant modification. Finally, the minor difference of lubricant capacity between Compritol HD5 ATO and Compritol 888 ATO has no consequence in compression practice. The presence of polyethylene glycol behenate does not decrease the glyceryl dibehenate compression functionality. This study concludes that Compritol HD5 ATO could be a very interesting excipient because it associates the glyceryl dibehenate lubricant capacity with the polyethylene glycol behenate-specific capacity in terms of dissolution enhancement.

Chemistry, Pharmaceutical↗