[Syncope as a cardiologic problem].

Abstract

Syncope is a frequent clinical event. It is mainly caused by a suddenly reduced cerebral blood flow. There are two reasons for sudden cerebral underperfusion: cardiogenic - associated with cardiac disorders and neurocardiogenic - resulting from a sudden fall of arterial blood pressure due to impaired autoregulation of the circulation. Cardiogenic syncopes prevail in cardiac diseases associated with impaired blood flow and cardiac arrhythmias. They develop in aortic stenosis, hypertrophic cardiomyopathy, atrial myxoma, myocardial infarction, pulmonary embolism, cardiac tamponade. Cardiac arrhythmias associated with syncope include ventricular tachycardia, supraventricular tachycardia in the preexcitation syndrome, sinus bradycardia, II degrees and III degrees atrioventricular block, atrial fibrillation with rapid ventricular response. The prognostic value and pathomechanisms loss of consciousness in these disease states have been discussed. Neurocardiogenic syncopes include vasovagal syncope, carotid sinus syndrome, orthostatic hypotension, event-induced syncope. It is frequently difficult to establish the reason for syncope. Physical examination and a history should be taken first followed by noninvasive studies such as standard ECG, exercise testing, carotid sinus compression, Holter monitoring, tilt testing, signal-averaged ECG. Noninvasive diagnosis helps establish the cause of syncope in 53-62% of cases and is indispensable before proceeding to electrophysiological testing. Such testing should be limited to patients with organic heart disease, in whom previous examinations did not reveal the etiology of loss of consciousness.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Bacior, A Curyło, J Kochman, A Stochmal, K Kawecka-Jaszcz. 1996. [Syncope as a cardiologic problem].. https://pubmed.ncbi.nlm.nih.gov/8927755/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A new pressure attenuation index to evaluate retinal circulation. A link to protective factors in diabetic retinopathy.

BACKGROUND: Low ocular perfusion pressure (two thirds of mean arterial pressure minus intraocular pressure) and myopia have been associated with protection of the retina from clinical diabetic retinopathy. This prompts the question as to whether myopia's protective role could also be a pressure effect, given that pressure could be dissipated in the longer arteriole tree of the myopic eye. METHODS: We combined the Ohm, Poiseuille, and Murray laws to derive the following new formulation: the pressure attenuation along a vessel varies directly with its length and inversely with its diameter. A mean pressure attenuation index was calculated for 22 healthy control subjects, 25 patients with axial myopia, and 6 patients with retinitis pigmentosa using digitized fundus images. RESULTS: The myopic arteriolar tree would produce a 16% greater pressure attenuation than that of controls (P = .002), with a linear relationship between mean pressure attenuation index and axial length (r = 0.93). Mean pressure attenuation index of the group with retinitis pigmentosa is increased 67% above that of controls, which is calculated to contribute an additional 10 mm Hg of pressure dissipation along their retinal arteriolar system. CONCLUSIONS: Pressure attenuation in retinal arterioles is directly proportional to the length and inversely proportional to the diameter of the arteriole segment being measured. CLINICAL RELEVANCE: A pressure attenuation index may be important in light of the entities known or presumed to protect the retina from diabetic retinopathy. The results support the hypothesis that low-end arteriolar pressure is a common denominator for many protective conditions in diabetic retinopathy.

Blood Circulation

Validation of haemodialysis recirculation and access blood flow measured by thermodilution.

BACKGROUND: Recirculation (R) and access blood flow (Qac) measurements are considered useful indicators of adequate delivery of haemodialysis. It was the purpose of this study to compare measurements of R and Qac obtained by two different techniques which are based on the same principle of indicator dilution, but which differ because of the characteristics of the injection and detection of the different indicators used. METHODS: Recirculation measured by a thermal dilution technique using temperature sensors (BTM, Fresenius Medical Care) was compared with recirculation measured by a validated saline dilution technique using ultrasonic transducers placed on arterial and venous segments of the extracorporeal circulation (HDM, Transonic Systems, Inc.). Calculated access flows were compared by Bland Altman analysis. Data are given as mean +/- SD. RESULTS: A total of 104 measurements obtained in 52 treatments (17 patients, 18 accesses) were compared. Recirculation measured with correct placement of blood lines and corrected for the effect of cardiopulmonary recirculation using the 'double recirculation technique' was -0.02 +/- 0.14% by the BTM technique and not different from the 0% measured by the HDM technique. Recirculation measured with reversed placement of blood lines and corrected for the effect of cardiopulmonary recirculation was 19.66 +/- 10.77% measured by the BTM technique compared with 20.87 +/- 11.64% measured by the HDM technique. The difference between techniques was small (-1.21 +/- 2.44%) albeit significant. Access flow calculated from BTM recirculation was 1328 +/- 627 ml/min compared with 1390 +/- 657 ml/min calculated by the HDM technique. There was no bias between techniques. CONCLUSION: BTM thermodilution yields results which are consistent with the HDM ultrasound dilution technique with regard to both recirculation and access flow measurement.

Blood Circulation