Search PubMedSearch

PubMed · 8910960

Predictive diagnostics for logistic models.

Abstract

Novel methodology is implemented to assess the predictive power of covariate information associated with sequential binary events. Logistic models are first fitted on the basis of a subset of the observations and then evaluated sequentially on the rest. The probabilistic forecasts are compared to the outcomes via a scoring function, but as most validation samples are small, the usual reference distribution for the test statistics is inadequate. However, bootstrap-based distributions can easily be constructed. The first example pertains to the evaluation of screening tests for major depression. It illustrates that goodness-of-fit and predictive assessments lead to the selection of very different models. The second example deals with the prediction of a major event in the natural history of HIV-induced disease. It shows that this type of analysis can reveal features missed by other approaches.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Seillier-Moiseiwitsch. 1996-10-30. Predictive diagnostics for logistic models.. https://doi.org/10.1002/(sici)1097-0258(19961030)15%3A20%3C2149%3A%3Aaid-sim360%3E3.0.co%3B2-h

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Detection of duck hepatitis B virus DNA fragments using on-column intercalating dye labeling with capillary electrophoresis-laser-induced fluorescence.

A rapid on-column DNA labeling technique is used to detect viral restriction DNA fragments by capillary electrophoresis-laser induced fluorescence detection. Intercalating dyes such as POPO3 or ethidium homodimer-2 are incorporated into the detection buffer. The cationic dyes migrate into the capillary during electrophoresis and bind to the oppositely migrating DNA fragments. A post-column sheath-flow fluorescence detector is used in the experiment. Excellent labeling efficiency is achieved at minimal background fluorescence by diluting the dyes to between 1 x 10(-7) M and 5 x 10(-7) M in a buffer with low ionic strength relative to the running buffer within the capillary. This dilute sheath-flow buffer allows stacking of dye molecules inside the capillary when an electric field is applied. Calibration curves using a series of DNA size markers (between 72 and 1353 base pairs) were linear over an order of magnitude in DNA concentration. Sensitivity also increased linearly with fragment length, and detection limits ranged from 4 x 10(-14) M to 5 x 10(-13) M for the size-standards. Analysis of cloned viral DNA using duck hepatitis B virus demonstrated a concentration detection limit of 3.9 x 10(-16) M. Last, the technique produced very high separation efficiency, 14 x 10(6) theoretical plates which is greater than 47 x 10(6) plates m-1, for the duck hepatitis B viral genome.

Calibration

Adaptive calibration of imaging array detectors.

We present two methods for nonuniformity correlation of imaging array detectors based on neural networks; both exploit image properties to supply lack of calibrations and maximize the entropy of the output. The first method uses a self-organizing net that produces a linear correction of the raw data with coefficients that adapt continuously. The second method employs a kind of contrast equalization curve to match pixel distributions. Our work originates from silicon detectors, but the treatment is general enough to be applicable to many kinds of array detectors like those used in infrared imaging or in high-energy physics.

Calibration

Chemiluminescence detection of heme proteins separated by capillary isoelectric focusing.

Chemiluminescence detection was combined with capillary isoelectric focusing to perform protein analysis with high sensitivity. Luminol-H2O2 chemiluminescence was utilized, and heme proteins such as cytochrome c, myoglobin and peroxidase were analyzed. The proteins were focused by use of Pharmalyte 3-10 as ampholytes. Hydroxypropylmethyl-cellulose was added to the sample solution in order to easily reduce protein interactions with the capillary wall as well as the electroendoosmotic flow. The focused proteins were transported by salt mobilization to chemiluminescence detection cell equipped with an optical fiber. The present method showed significantly high sensitivity and wide dynamic range; the detection limit for cytochrome c was 6 x 10(-9) M and the linear dynamic range was greater than two-orders of magnitude (up to 2 x 10(-6) M).

Calibration