Search PubMedSearch

PubMed · 8904901

Activated platelet aggregates in thrombotic thromboctyopenic purpura: decrease with plasma infusions and normalization in remission.

Abstract

Circulating activated platelet aggregates (aPA) were assayed by flow cytometry employing mAb alpha-CD62p in eight patients with thrombotic thrombocytopenic purpura (TTP). Elevation of aPA was observed in all patients in active stages of TTP; aPA normalized in remission. Plasma infusions with plasmapheresis decreased aPA in responding patients. The rise and fall of aPA preceded relapses and improvements, respectively. These changes were seen prior to the traditional indicators, LDH, haematocrit, and platelet count. Incubation of plasma from TTP patients with normal whole blood induced formation of aPA; this effect was significantly greater than that of plasmas from ITP patient controls (P < 0.01), suggesting the presence of an aPA-promoting factor in TTP plasma. Parallel experiments using a platelet aggregometer failed to detect effect of TTP plasma on normal blood. In summary, aPA appear to be a marker of disease activity, rising with relapse, falling with plasma therapy, and normalizing in remission. The flow cytometric assay of aPA is more sensitive than aggregometry in detecting the putative aPA-promoting factor in TTP.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y S Ahn, W Jy, L Kolodny, L L Horstman, W W Mao, P A Valant, R C Duncan. 1996. Activated platelet aggregates in thrombotic thromboctyopenic purpura: decrease with plasma infusions and normalization in remission.. https://doi.org/10.1046/j.1365-2141.1996.d01-1902.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Evaluation of an alternative to the Kolmogorov-Smirnov test for flow cytometric histogram comparisons.

BACKGROUND: The Kolmogorov-Smirnov test is a valid statistical test for comparing distributions that has been recommended for flow cytometric histogram analysis. However, this test is frequently found to be too sensitive for flow cytometric histogram comparisons. Here, a parametric alternative to the Kolmogorov-Smirnov test is proposed that is based on fitting suitable models to flow cytometric data. METHODS: Several flow cytometric histograms derived from cell surface immunophenotyping for intercellular adhesion molecule-1 (ICAM-1) on K562 cells were analyzed using numerical modeling. The prediction intervals derived from the modeling were used for decision making. RESULTS: The residuals after peak fitting flow cytometric data are normally distributed and this permits the use of the prediction limit methodology. The usefulness of the approach for analyzing flow cytometry histograms is examined and the method is shown to avoid the "sensitivity" disadvantages associated with the Kolmogorov-Smirnov test. CONCLUSIONS: The prediction limit method is a viable alternative to the Kolmogorov-Smirnov method.

Flow Cytometry

Characterization of the sensitivity of side scatter in a flow-stream waveguide flow cytometer.

BACKGROUND: We previously reported a new optical configuration, in which both the side scatter and the fluorescence are collected using the index-guided, total internal reflection of a flow stream in air (the flow-stream waveguide). METHODS: Using a mixture of 0.202-microm and 0.093-microm diameter polystyrene beads, we have characterized the side scatter (SSC) sensitivity of a custom-built flow cytometer (miniFlo) which incorporates a flow-stream waveguide. RESULTS: The SSC-triggered SSC signal of 0.093-microm polystyrene beads in water was almost baseline resolved from the background. We also measured the SSC-triggered SSC signal of the same beads in water on our FACScan, which is a commercial unit with the conventional optical arrangement that uses a custom imaging objective to collect light from a sheath flow cuvette in perpendicular direction-the signal from 0.093-microm beads was not resolved from the background. CONCLUSIONS: The SSC sensitivity of miniFlo is one of the best reported in the literature. Cytometry 37:160-163, 1999. Published 1999 Wiley-Liss, Inc.

Flow Cytometry

Multicenter study of reference stabilized human blood for lymphocyte immunophenotyping quality control in flow cytometry. GEIL.

The development of automated methods and normative rules, as well as the dependence of some therapeutic approaches on lymphocyte subsets counts, has led to the appearance of calibration reagents. Such reagents are expected to perform equally well in very different settings. We developed a multicenter trial to evaluate the performance of a new quality control reagent, i.e., stabilized blood to be used in immunophenotyping laboratories. Aliquots of the same batch of stabilized blood were shipped to 45 French and Belgian laboratories on a Monday and had to be tested for percentages and absolute counts of at least CD3-, CD4-, and CD8-positive lymphocytes on 4 consecutive days. The percentages and absolute counts obtained on each assay were recorded, as well as the type of lysis used, the trademark of reagents, and the brand of flow cytometer. The mean values collected did not differ significantly from those expected by the manufacturer. Absolute counts generated through one-step techniques displayed lower CVs. This new reagent therefore appears to be a robust product, liable to yield consistent results in the array of different conditions represented by routine laboratories, and it could be useful for quality control procedures.

Flow Cytometry