Search PubMedSearch

PubMed · 8900447

1996 Lab Guide.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

1995-08-15. 1996 Lab Guide.. https://pubmed.ncbi.nlm.nih.gov/8900447/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Quantification and interpretation of total petroleum hydrocarbons in sediment samples by a GC/MS method and comparison with EPA 418.1 and a rapid field method.

Total petroleum hydrocarbons (TPH) as a lumped parameter can be easily and rapidly measured or monitored. Despite interpretational problems, it has become an accepted regulatory benchmark used widely to evaluate the extent of petroleum product contamination. Three currently used methods (GC/MS, conventional EPA 418.1, and a rapid field method PetroFLAG) were performed to quantify the TPH content in samples collected from a site contaminated by transformer oil. To standardize the method and improve the comparability of TPH data, crucial GC-based quantification issues were examined, e.g., quantification based on internal standards (ISTD) vs external standards (ESTD), single vs multiple ISTD, and various area integration approaches. The interpretation of hydrocarbon chromatographic results was examined in the context of field samples. The performance of the GC/MS method was compared with those of EPA 418.1 and PetroFLAG. As a result, it was observed that the ISTD quantification method was preferred to the ESTD method, multiple ISTD might be better than single ISTD, and three different area integration approaches did not have a significant effect on TPH results. Evaluation of the chromatograms between a reference sample and three unknown samples showed that the extent of contamination varied appreciably with sample depth. It was also found that there existed a good positive correlation between GC/MS and both EPA 418.1 and PetroFLAG, and that EPA 418.1 produced the higher overall estimate while GC/MS and PetroFLAG resulted in lower, more statistically comparable TPH values.

Chemistry Techniques, Analytical

Determination of the entrapped volume of liposomes: dilution method.

A novel method was developed for the determination of the entrapped volume of liposomes. The obtained values of the entrapped volume by our "dilution method" agreed very well with those of the conventional "quenching method." The dilution method also offered the great advantages of simple procedure and high reproducibility. The principle and validity of our method are discussed.

Chemistry Techniques, Analytical