Three-dimensional strain-rate imaging.

Abstract

Strain-rate imaging uses large velocity encoding gradients to obtain measurements of velocity that are extremely insensitive to the effects of random noise. The spatial differential of velocity yields the velocity gradient from which the strain-rate and twist-rate tensors can be determined. These tensors represent the distortion of the material and are of interest in the analysis of the dynamic behavior of living tissue (e.g., that of the myocardium). This work presents a new technique that uses the magnitude of the signal in the velocity encoded data to measure through-plane velocity variations at the resolution of the voxel size. The magnitude of the MR signal contains information about the range of phases present within a voxel. When the phase is dependent on the velocity (as in phase velocity imaging), the magnitude contains information about the range of velocities within a voxel. The method presented in this work uses unbalanced slice-refocusing gradients to sample the magnitude variation introduced by the interaction of velocity encoding gradients with spatially dependent velocities. The previously developed in-plane velocity gradient methods can be easily integrated with this new through-plane measurement to characterize the deformation of the myocardium in three spatial dimensions with high accuracy. The applicability of these methods is demonstrated theoretically, in phantoms and in vivo.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M D Robson, R T Constable. 1996. Three-dimensional strain-rate imaging.. https://doi.org/10.1002/mrm.1910360406

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Fundamental study of turbo spin echo sequence with driven equilibrium pulse].

UNLABELLED: When MR images are obtained with the turbo spin echo (TSE) sequence, DRIVE can be used as a sequence in which the driven equilibrium pulse (DE pulse), a reset pulse, is applied at the TSE echo train to accelerate relaxation time and return to the equilibrium of Mz magnetization. In this study, we examined the extent to which TR could be shortened in DRIVE and how the other parameters of the turbo spin echo sequence influence it. RESULTS: 1) DRIVE is effective when the T2 value is long. 2) It is necessary to set TR at 1000 ms or more to obtain image contrast with free water and fat in T2-weighted images for which a conventional turbo spin echo sequence using DRIVE is employed in clinical examination. 3) It is not necessary to consider the influence of the TSE factor when using DRIVE.

Echo-Planar Imaging↗

Spatial and temporal characteristics of physiological noise in fMRI at 3T.

RATIONALE AND OBJECTIVES: Physiological noise in blood oxygen level-dependent functional magnetic resonance imaging (BOLD fMRI) has been shown to have characteristics similar to the BOLD signal itself, suggesting that it may have a vascular dependence. In this study, we evaluated the influence of physiological noise in fMRI as revealed by the differences in vasculature sensitivity of gradient-echo echo-planar imaging (GE-EPI) and spin-echo EPI (SE-EPI). MATERIALS AND METHODS: The contribution of physiological noise to the fMRI signal during activation of the visual cortex was assessed by comparing its temporal characteristics with respect to echo time (TE), using both GE-EPI and SE-EPI. The correlation of the noise in fMRI with apparent diffusion coefficient (ADC) and the number of components required to describe its variance, as determined by principal-component analysis (PCA), were also assessed. RESULTS: The SE-EPI data were less affected by a TE-dependence of noise, in contrast to the apparent physiological noise in GE-EPI. Voxel-wise analysis revealed that total apparent noise increased as ADC values increased, and the relationship was different for GE-EPI and SE-EPI. PCA revealed that while the number of components characterizing the noise in SE-EPI data increased in a TE-dependent manner, approaching that of white noise at long echo time, the number of components from GE-EPI data was TE-independent. CONCLUSIONS: The difference in sensitivities to physiological noise between SE-EPI and GE-EPI suggests that extravascular BOLD processes around draining veins contribute significantly to physiological noise in BOLD fMRI, and the suppression of this noise component may enhance SE-EPI BOLD sensitivity at higher fields.

Echo-Planar Imaging↗

[Basis examination of image contrast in fluid attenuated inversion recovery balanced turbo field echo (FLAIR-B-TFE)].

PURPOSE: We have made clinical use of FLAIR-B-TFE, where an image is taken at the null point (NP) of water with the addition of inversion pulse to B-TFE, and obtained highly effective results in many areas. Changes in NP and image contrast were reviewed to optimize this sequence. MATERIALS AND METHODS: Oil, water, and venous blood before and after Gd-DTPA dispensation as well as diluted (by 500/4000 times) Gd-DTPA solution were designated as the standard phantoms wherein shot intervals (SI), scan modes, k-space ordering, TFE factor, dummy pulse, and presence or absence of IR pulses were changed. RESULTS: What affects the NP of water most is the SI, and unless SI is long enough so that the longitudinal magnetization of water can recover to the full, NP will change. There is little difference in image contrast between the NP of water and that of blood, and a sluggish blood signal ascendance will necessitate intentional blood signal ascendance by contrast-enhancement. The signal intensity of blood after the angiographies will almost reach a plateau at an SI level of more than 2000 ms. Therefore, it is appropriate to apply SI 2000 ms, in view of the time necessary for contrast-enhancement.

Echo-Planar Imaging↗