Nonstandard imaging methods in electron microscopy.

Abstract

A rigorous treatment of image formation, taking into account inelastic scattering and partially coherent illumination, is given for the CTEM. The results also hold for a STEM if the momentum vectors of the incident and outgoing waves are interchanged and the flight direction of the electrons is reversed. A generalized optical theorem is found which connects the anti-Friedel part of the elastic scattering amplitude with the squares of the elastic and inelastic scattering amplitudes. This theorem has important consequences for all approximation methods. For example, it shows that inelastic scattering influences the elastic scattering amplitude. It is further shown that the observed wings in optical diffractograms, obtained from micrographs of amorphous material taken using tilted beam illumination, can only be explained if double scattering (elastic and inelastic) is assumed. Hollow-cone illumination strongly suppresses the structural noise in the phase contrast image. The corresponding phase contrast transfer function (PCTF) is calculated for two different cone angles, assuming that no beam-limiting aperture is present. In addition, the PCTFs of a corrected microscope are calculated for two different illumination modes, one yielding negative and the other positive phase contrast. Finally, the contrast transfer has been investigated for a stem operating with a split detector.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Rose. 1977. Nonstandard imaging methods in electron microscopy.. https://doi.org/10.1016/s0304-3991(76)91538-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Pulsing mercury arc lamps for uncaging and fast imaging.

It is shown that the light intensity from a mercury short arc light bulb can be boosted to about 100 times its steady-state value for a period of about 1 ms by superimposing a current pulse of up to 100 amperes in magnitude and 1-2 ms in duration on a simmer current of 3 amperes. The output spectrum changes in a remarkable way from a line to a broadband distribution. The radiance delivered during a 1-ms pulse is comparable to what can be obtained from a Xe flash bulb. The lack of a high voltage ignition pulse accounts for an extreme reduction of the electrical artifact seen for the pulsed Hg bulb as compared to a Xe flash lamp. Possible applications include the release of caged compounds, high speed imaging, and wavelength ratio-imaging without filter switching.

Lighting↗