Search PubMed⌕ Search

PubMed · 8858721

On-line exit dose profile measurements by a diode linear array.

Abstract

The possibility of using a commercial diode linear array (BMS Schuster Inc.) in on-line portal dosimetry has been investigated. The system is composed of 88 equispaced diodes (distance between diodes, 0.5 cm; detection area, 2.5 x 2.5 mm2). The ability to measure exit dose profiles has been demonstrated by comparing relative exit dose profiles measured by an ionization chamber (NE 2571) with 'portal' profiles measured by the diode array on a number of homogeneous and inhomogeneous phantoms in 6 MV x-ray beams (from a Clinac Varian 6/100). The influence of the variation of the scattered radiation at the exit level with respect to the detector level has been discussed and investigated by varying the air gap (from 0 to 80 cm for a homogeneous phantom and from 0 to 25 cm for inhomogeneous phantoms) as well as the field width. A good agreement (maximum difference 3.8%; 2.5% when the array was positioned in contact with the phantoms) between 'portal' profiles and exit dose profiles in both homogeneous and inhomogeneous phantoms has been found if the array-phantom distance is kept below 7.5 cm. Results indicate that the system should be suitable for applications in transit dosimetry.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Fiorino, C Uleri, G M Cattaneo, R Calandrino. 1996. On-line exit dose profile measurements by a diode linear array.. https://doi.org/10.1088/0031-9155%2F41%2F8%2F004

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stochastic simulation of daily air temperature and precipitation from monthly normals in North America north of Mexico.

A simple, stochastic daily temperature and precipitation generator (TEMPGEN) was developed to generate inputs for the study of the effects of climate change on models driven by daily weather information when climate data are available as monthly summaries. The model uses as input only 11 sets of monthly normal statistics from individual weather stations. It needs no calibration, and was parameterized and validated for use in Canada and the continental United States. Monthly normals needed are: mean and standard deviation of daily minimum and maximum temperature, first and second order autoregressive terms for daily deviations of minimum and maximum temperatures from their daily means, correlation of deviations of daily minimum and maximum temperatures, total precipitation, and the interannual variance of total precipitation. The statistical properties and distributions of daily temperature and precipitation data produced by this generator compared quite favorably with observations from 708 stations throughout North America (north of Mexico). The algorithm generates realistic seasonal patterns, variability and extremes of temperature, precipitation, frost-free periods and hot spells. However, it predicts less accurately the daily probability of precipitation, extreme precipitation events and the duration of extreme droughts.

Air↗

Blends of poly(epsilon-caprolactone) and intermediate molar mass polystyrene as Langmuir films at the air/water interface.

Poly(epsilon-caprolactone)/polystyrene (PCL/PS) blends, where nonamphiphilic PS is glassy in the bulk state at the experimental temperature of 22.5 degrees C, are immiscible as Langmuir films at the air/water (A/W) interface. Surface pressure-area per monomer isotherm analyses indicate that the surface concentration of amphiphilic PCL is the only factor influencing the surface pressure below the collapse transition. For PS-rich blends, Brewster angle microscopy (BAM) studies at the A/W interface and atomic force microscopy studies on Langmuir-Schaefer films reveal that PS nanoparticle aggregates formed at very low surface pressures can form networks upon further compression. The morphologies seen in PS-rich blends (networklike rings) are consistent with a recent study of a nonamphiphilic polyhedral oligomeric silsesquioxane (POSS), octaisobutyl-POSS, blended with amphiphilic poly(dimethylsiloxane), suggesting that the nonamphiphilic PS aggregates at the A/W interface produce domains with dipole densities that differ from that of pure PCL. In all composition regimes, the amphiphilic PCL phase tends to spread and form a continuous surface layer at the A/W interface, while simultaneously improving the dispersion of nonamphiphilic PS domains. During film expansion, BAM images show a gradual change in the surface morphology from highly continuous networklike structures (PS-rich blends) to broken ringlike structures (intermediate composition) to small discontinuous aggregates (PCL-rich blends). This study provides valuable information on the morphological evolution of semicrystalline PCL-based polymer blends confined in a "two-dimensional" geometry at the A/W interface and fundamental insight into the influence of microstructure (domain size, phase-separated structures, crystalline morphology, etc.) on the interfacial properties of blends as Langmuir films.

Air↗

Prediction of air temperature for thermal comfort of people in outdoor environments.

Current thermal comfort indices do not take into account the effects of wind and body movement on the thermal resistance and vapor resistance of clothing. This may cause public health problem, e.g. cold-related mortality. Based on the energy balance equation and heat exchanges between a clothed body and the outdoor environment, a mathematical model was developed to determine the air temperature at which an average adult, wearing a specific outdoor clothing and engaging in a given activity, attains thermal comfort under outdoor environment condition. The results indicated low clothing insulation, less physical activity and high wind speed lead to high air temperature prediction for thermal comfort. More accurate air temperature prediction is able to prevent wearers from hypothermia under cold conditions.

Air↗