Search PubMed⌕ Search

PubMed · 8853015

Cloning single-stranded DNA.

Abstract

DNA sequence and expression analyses have greatly benefited from using M13 and pUC derived cloning vectors and their polycloning sites. A chronology of the original concepts and experiments is reviewed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Messing. 1996. Cloning single-stranded DNA.. https://doi.org/10.1007/bf02762411

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Membrane-mediated ultrafast restriction digestion and subsequent rapid gel microchip electrophoresis of DNA.

Ultrafast, membrane-mediated restriction digestion of DNA molecules followed by rapid gel microchip electrophoresis of the resulting fragments is described. Combination of restriction endonuclease digestion on small pore-size microfibrous membranes with sample loading and electrophoresis analysis in a multilane (up to 96) format resulted in very fast restriction digest based microscale DNA analysis. Complete digestion of several nanogram target DNA was accomplished on the microporous membrane at room temperature just in a few minutes with a single or a combination of various restriction enzymes, using only submicroliter quantities of samples and reagents. The reaction mixture containing membrane also served as sample loading device for the subsequent gel microchip electrophoresis based analysis. This work establishes methods for high-speed, high-throughput DNA analysis, featuring extremely low sample and reagent consumption, and fast restriction digestion in combination with sample loading and rapid gel microchip analysis of the resulting fragments. The entire restriction digestion, sample loading and electrophoresis analysis process required less than 20 min.

Bacteriophage phi X 174↗

DNA separation by microchip electrophoresis using low-viscosity hydroxypropylmethylcellulose-50 solutions enhanced by polyhydroxy compounds.

Low-viscosity polymer solutions have potential for double-stranded (ds) DNA separations in micrototal analysis systems (micro-TAS). In this paper, we report dilute, low-viscosity hydroxypropylmethylcellulose-50 (HPMC-50, 11.5 kDa) solutions containing polyhydroxy additives as separation media. Predominant operational variables, such as applied electric field strength, fluorescent intercalator (YOPro-1) concentration, polymer concentration, and additive concentration, are thoroughly investigated. Fast (within 170 s) and excellent separation of DNA restriction fragments ranging in size from 72 to 1353 base pairs (bp) is achieved in a 30 mm length channel of polymethylmethacrylate (PMMA) microchips at an electric field strength of 300 V/cm, by introducing 8% mannitol, 8% glucose or 10% glycerol additives into a 2% HPMC-50/1 x Tris-borate-EDTA (TBE) solution. The low-viscosity (40 cP) matrix formulation provides both coating of the microchannels and separation of DNA in one step. The performance in the solution surpasses that in highly concentrated HPMC-50 solution. In addition, separation using 1xTris-EDTA buffer in the 2% HPMC-50 matrix containing polyhydroxy additives also exhibits a notably increased performance. This is presumably due to formation of hydrogen-bonding interactions of polyhydroxy additives with HPMC-50 matrix and DNA so as to increase the coupling interactions between matrix and DNA molecules during electrophoresis. The result reflects that boric acid is not a prerequisite in polyhydroxy-enhanced HPMC-50 solution for separation.

Bacteriophage phi X 174↗

Biaxial flex-fatigue and viral penetration of natural rubber latex gloves before and after artificial aging.

Barrier integrity of unaged and oven-aged (at 70 degrees C) natural rubber latex examination gloves was assessed with a biaxial flex-fatigue method where failure was detected electronically, and by live viral penetration testing performed according to a modified version of ASTM F1671-97a. When no change in barrier properties was detected during flex testing, no virus passage was found after viral challenge. Conversely, when a change in the barrier properties was indicated by the electrical signal, virus passage was found in 74% of the specimens. Flex-fatigue results indicated that unaged test specimens from powdered (PD) and powder-free (PF) nonchlorinated gloves had significantly longer fatigue lives than powder-free chlorinated (CL) gloves from the same manufacturer. Biaxial flexing of oven-aged glove specimens showed a marginal increase in fatigue life for the PF gloves, but no increase for the PD gloves. The fatigue life of the CL gloves was observed to increase significantly after oven aging. However, this appears to be due to a design feature of the test apparatus, wherein peak volume displacement of the worked specimen is held constant. An aging-induced change in the viscoelastic properties of the CL gloves-permanent deformation of the specimens early in the fatigue test-relieves the stress magnitude applied as the test progresses. Thus, permanent deformation acts as a confounding factor in measuring durability of latex gloves by fixed displacement flex-fatigue.

Bacteriophage phi X 174↗