Coronary stents were developed to overcome the two main limitations of balloon angioplasty, acute occlusion and long-term restenosis. Coronary stents can tack back intimal flaps and seal the dissected vessel wall, thereby treating acute or threatened vessel closure after unsuccessful balloon angioplasty. After successful balloon angioplasty, stents can prevent late vessel remodeling (chronic vessel recoil) by mechanically enforcing the vessel wall and resetting the vessel size, resulting in a low incidence of restenosis. All currently available stents are composed of metal, and the long-term effects of their implantation in the coronary arteries are still not clear. Because of the metallic surface, they are also thrombogenic; therefore, rigorous antiplatelet or anticoagulant therapy is theoretically required. Furthermore, they have an imperfect compromise between scaffolding properties and flexibility, resulting in an unfavorable interaction between stents and unstable or thrombus-laden plaque. Finally, they still induce substantial intimal hyperplasia that may result in restenosis. Future stents can be made less thrombogenic by modifying the metallic surface or coating it with an antithrombotic agent or a membrane eluting an antithrombotic drug. The unfavorable interaction with the unstable plaque and the thrombus burden can be overcome by covering the stent with a biological conduit, such as a vein, or a biodegradable material that can be endogenous, such as fibrin, or exogenous, such as a polymer. Finally, the problem of persisting induction of intimal hyperplasia may be overcome with the use of either a radioactive stent or a stent eluting an antiproliferative drug.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Ozaki, A G Violaris, P W Serruys. New stent technologies.. https://doi.org/10.1016/s0033-0620(96)80022-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Left atrial myxoma presenting with myocardial infarction. Case report and review of the literature.

Coronary artery embolization is an extremely rare and potentially lethal complication of atrial myxomas. We present a case report and a literature review of this clinical association. A 53-year-old woman presented with an acute infero-lateral myocardial infarction. Coronary angiography performed 1 h after the onset of pain disclosed an abrupt stop and multiple embolization of the peripheral right coronary artery (RCA). A transthoracic echocardiographic study revealed the presence in the left atrium of an echogenic, mobile mass, compatible with myxoma. The tumour was successfully removed surgically 2 weeks later and the patient is doing well one year post operatively.

Coronary Angiography

Late clinical outcomes of cordis tantalum coronary stenting without anticoagulation.

This study was performed to evaluate clinical and angiographic restenosis rates after successful Cordis coronary stent implantation and intravascular ultrasound images were acquired to compare results with quantitative angiographic findings in a subgroup of patients. We conclude that (1) the angiographic restenosis rate of Cordis stent was 19%, which was comparable to that of other slotted-tube stents, and (2) the quantitative coronary angiographic calliper method is reliable for assessing Cordis in-stent restenosis, especially diffuse in-stent restenosis.

Coronary Angiography