Search PubMed⌕ Search

PubMed · 8796201

Gain changes in the accommodative convergence cross-link.

Abstract

The output of the accommodative vergence cross-link, the AC/A ratio, was measured before and after subjects viewed through a telestereoscope which increased their interocular separation (pd) approximately fourfold. The initial paradigm was designed to force an increase in the AC/A ratio in that subjects alternately fixated targets set at differing distances. In this paradigm, the varying vergence demands could not be met by a constant increase in phasic or tonic vergence responses. In a second paradigm, only one target was viewed at a fixed position from the eye. Now the constant vergence demand could be met by a set increase in phasic and/or tonic vergence. A significant increase in the AC/A ratio was found in the two-target study but not in the single-target study. Increases in the accommodative vergence gain did show considerable individual differences. Tonic vergence changes were interpolated from the data. This parameter increased significantly in both cases but more so when two targets were alternately fixated. This finding is consistent with current near triad models which predict that accommodative convergence input acts along with disparity vergence input to increase tonic levels of convergence. When AC/A ratios were calculated using clinical measures of the phoria at 6 and 0.4 m, increases were found in the two-target study and to a lesser degree in the single-target study. This clinical method of AC/A measure appears to have been confounded by changes in tonic vergence.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W R Bobier, M McRae. 1996. Gain changes in the accommodative convergence cross-link.. https://pubmed.ncbi.nlm.nih.gov/8796201/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Conceptual model of human blur perception.

An empirically based, conceptual model of human blur perception is presented. It incorporates the concepts of blur detection and blur discrimination in depth, and across the central and peripheral retina, in two- and three-dimensional visual space. Key aspects of the model are its dynamic nature, predictability regarding the blur-based depth-ordering of objects, patterns of retinal defocus with far and near viewing, and interactions related to retinal defocus between the central and peripheral retina. Furthermore, a two-dimensional schematic representation of the blur-free region during near viewing is depicted in dioptric space. This model has implications with respect to accommodative control, depth perception, and refractive error development and progression.

Accommodation, Ocular↗

The effect of human in vivo accommodation on crystalline lens stability.

AIM: To determine the effect of human in vivo accommodation on the stability of the crystalline lens. METHODS: Using a dual Purkinje image (DPI) eyetracker, the phase-time difference and amplitudes of Purkinje images I (P(I)) and IV (P(1V)) were measured in 37 normal emmetropic subjects (34 women and 3 men; mean age 19.8, range 18-22 years) when they changed focus from 70 to 15 cm and simultaneously rotated their heads horizontally from side to side or made horizontal saccades between two targets 6.8 degrees apart. RESULTS: When the subjects changed focus from 70 to 15 cm and rotated their heads or made eye saccades, the phase-time difference between P(I) and P(IV) decreased. During saccades, the amplitude of both P(I) and P(IV) overshoots significantly increased with focus at 15 cm; however, their ratio (P(IV) overshoot amplitude/P(I) overshoot amplitude) significantly declined. CONCLUSIONS: The lens is stable during accommodation. The implications of these findings on the mechanism of accommodation are discussed.

Accommodation, Ocular↗

Synchrony dual-optic accommodating intraocular lens. Part 2: pilot clinical evaluation.

PURPOSE: To evaluate the clinical outcomes of an accommodating dual-optic intraocular lens (IOL). SETTING: Private practice and university centers. METHODS: A prospective noncomparative case series with retrospective control comprised 21 patients (26 eyes) scheduled for small-incision extracapsular cataract extraction by phacoemulsification with implantation of the Synchrony dual-optic accommodating IOL (Visiogen) (accommodating IOL group) and 10 patients who had small-incision extracapsular phacoemulsification with implantation of a monofocal, single-optic IOL at least 6 months previously (control group). Patients were examined 1, 3, 6, and 12 months after surgery. Defocus curves in the accommodating IOL group were compared with those in the control group. The main outcome measures were postoperative distance uncorrected and best corrected visual acuity; near uncorrected, distance corrected, and near corrected visual acuity; and accommodative range based on defocus curves. RESULTS: Twenty-four eyes were available at the 6-month follow-up visit. All eyes had best corrected distance visual acuity of 20/40 or better, and 19 eyes (79%) had an uncorrected distance visual acuity of 20/40 or better. Uncorrected near visual acuity was 20/40 or better in all eyes. With distance correction, 23 eyes (96%) had an acuity of 20/40 or better at near. Defocus curve analysis suggested a mean accommodative range of 3.22 diopters (D) +/- 0.88 (SD) (range 1.00 to 5.00 D) in the accommodating IOL group and 1.65 +/- 0.58 D in the control group (range 1.00 to 2.50 D) (P<.05). CONCLUSION: The Synchrony dual-optic IOL shows promise as an option to provide accommodative function in pseudophakic patients.

Accommodation, Ocular↗