Search PubMed⌕ Search

PubMed · 8779759

Fixed prosthodontics: avoiding pulp death.

Abstract

Fixed prostheses & crowns have become a major part of dental services due to aging population & increase in retention of natural teeth. In some practices, alarming numbers of endodontic procedures are necessary because of pulp damage after prosthesis cementation. Third party payment companies show many teeth receiving crowns require endodontic therapy within 5 years. Following report describes: (1) 14 potential causes of endodontic need related to fixed prosthodontics; & (2) state-of-art concepts to prevent pulp damage.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

1995. Fixed prosthodontics: avoiding pulp death.. https://pubmed.ncbi.nlm.nih.gov/8779759/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

New abutment for a screw-retained, implant-supported crown.

The 1-piece, implant-supported abutment and crown, colloquially described as the UCLA abutment, commonly is used to fabricate single, screw-retained crowns. This abutment was designed to allow attachment of the crown directly to the implant and requires a waxing and casting procedure by a laboratory technician. A new prefabricated abutment has been developed that uses a similar approach but does not require the waxing and casting process. The PDQ abutment is made from a metal-ceramic alloy that is custom contoured by grinding to support a porcelain veneer. Porcelain then is fired to the contoured abutment to develop the 1-piece artificial crown. This article describes the use of the PDQ abutment.

Crowns↗

Marginal fit of metal ceramic restorations subjected to a standardized postsoldering technique.

The fit of a fixed partial denture (FPD) is fundamental for the clinical success of a restoration. When a postsoldering procedure is needed, a high-precision laboratory technique is necessary to not affect the fit of the FPD. This article evaluates whether a standardized postsoldering technique affected the marginal fit of a 3-unit high palladium alloy FPD. One hundred and eight measurements were made of 3-unit FPDs, fabricated in a high palladium alloy (2% Au-79% Pd-10% Cu-8% Ga) and constructed on 9 tin dies in vitro. After the castings were fabricated, specimens were measured at 3 specific points per abutment (distal, labial, lingual) before and after soldering. Differences were found in the marginal opening of both copings, before soldering (49.9 microm) and after soldering (48. 3 microm). There was no significant difference in the adaptation of the copings after the soldering procedure (P<.05).

Crowns↗

Evaluation of the dimensional changes and surface roughness of gold crowns cast with rapidly prepared phosphate-bonded investment: a pilot study.

STATEMENT OF PROBLEM: Accelerated bench-set and burnout schedules are used with little knowledge of the effect acceleration has on clinical factors determining casting success. PURPOSE: This pilot study investigated the effect of 2 rapid mold preparation schedules on full crown castings by comparing size, margin sharpness, and surface roughness. MATERIAL AND METHODS: Three groups of 10 crowns were cast with a type III gold alloy. All crowns were nominally identical, only their mold preparation schedules differed. Two groups used accelerated schedules; the third group was cast using a conventional schedule. Group comparisons were based on direct microscopic measurements of crown diameters (x50 magnification), and surface roughness was measured. Margin sharpness was judged by amount of marginal length lost in the axial direction as a result of the casting process. RESULTS: Measured crown diameters, indexing size for the 3 groups, were not significantly different. Crowns made with the conventional schedule had greater surface roughness, and better margin sharpness or length. CONCLUSION: Crowns were successfully cast using accelerated mold preparation techniques and considerable time was saved, but a small loss of margin length or fineness was observed.

Crowns↗