Search PubMedSearch

PubMed · 8778703

Sinus node dysfunction in tuberous sclerosis.

Abstract

Tuberous sclerosis is an autosomal dominant disease with potential for involvement of the skin, brain, lungs, kidneys, and heart. A case of prolonged sinus node pause and episodes of unresponsiveness in a 21-week-old infant with tuberous sclerosis is described. The infant subsequently underwent placement of an epicardial pacemaker. This case illustrates the importance of electrocardiographic studies in infants with tuberous sclerosis and seizure-like episodes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C G Cowley, L Y Tani, V E Judd, R E Shaddy. Sinus node dysfunction in tuberous sclerosis.. https://doi.org/10.1007/bf02505813

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Interactions between electronic article surveillance systems and implantable cardioverter-defibrillators.

BACKGROUND: In patients with implantable cardioverter-defibrillators (ICDs). inappropriate shocks have been reported with exposure to electronic article surveillance systems. The risk to patients with ICDs of walking through or lingering near surveillance systems requires further investigation. METHODS AND RESULTS: We evaluated the response in ICD function in 170 subjects during a 10- to 15-second midgate walk-through of and during extreme (2 minutes within 6 in of the gate) exposure to 3 common article surveillance systems. Complete testing was done in 169 subjects. During a 10- to 15-second (very slow) walk-through of the 3 surveillance systems, no interactions were observed that would negatively affect ICD function. During extreme exposure (169 subjects) and during extreme exposure and pacing via the ICD (126 subjects), interactions between the ICD and the article surveillance systems were observed in 19 subjects. In 7 subjects, this interaction was clinically relevant and would have likely (3 subjects) and possibly (4 subjects) resulted in ICD shocks. In 12 subjects, the interaction was minor. CONCLUSIONS: It is safe for a patient with an ICD to walk through electronic article surveillance systems. Lingering in a surveillance system may result in an inappropriate ICD shock.

Cardiac Pacing, Artificial

Septal Q waves in surface electrocardiographic lead V6 exclude minimal ventricular preexcitation.

Electrocardiograms of 37 consecutive patients with minimal preexcitation (i.e., PR >120 ms, QRS <120 ms) were compared before and after ablation with electrocardiograms of 37 age-matched patients with atrioventricular nodal reentrant tachycardia. The presence of a septal Q wave could be used to exclude minimal preexcitation with a high degree of reliability in both patients and controls before and after radiofrequency ablation.

Cardiac Pacing, Artificial