Search PubMedSearch

PubMed · 8746682

Fraction collection.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K D Altria. 1996. Fraction collection.. https://doi.org/10.1385/0-89603-315-5%3A99

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A molecular scanner to automate proteomic research and to display proteome images.

Identification and characterization of all proteins expressed by a genome in biological samples represent major challenges in proteomics. Today's commonly used high-throughput approaches combine two-dimensional electrophoresis (2-DE) with peptide mass fingerprinting (PMF) analysis. Although automation is often possible, a number of limitations still adversely affect the rate of protein identification and annotation in 2-DE databases: the sequential excision process of pieces of gel containing protein; the enzymatic digestion step; the interpretation of mass spectra (reliability of identifications); and the manual updating of 2-DE databases. We present a highly automated method that generates a fully annoated 2-DE map. Using a parallel process, all proteins of a 2-DE are first simultaneously digested proteolytically and electro-transferred onto a poly(vinylidene difluoride) membrane. The membrane is then directly scanned by MALDI-TOF MS. After automated protein identification from the obtained peptide mass fingerprints using PeptIdent software (http://www.expasy.ch/tools/peptident.html + ++), a fully annotated 2-D map is created on-line. It is a multidimensional representation of a proteome that contains interpreted PMF data in addition to protein identification results. This "MS-imaging" method represents a major step toward the development of a clinical molecular scanner.

Automation

Solution structure of the VEGF-binding domain of Flt-1: comparison of its free and bound states.

The extracellular portion of the VEGF and PlGF receptor, Flt-1 (or VEGFR-1), consists of seven immunoglobulin-like domains. The second domain from the N terminus (Flt-1D2) is necessary and sufficient for high affinity VEGF binding. The 1.7 A resolution crystal structure of Flt-1D2 bound to VEGF revealed that this domain is a member of the I-set of the immunoglobulin superfamily, but has several unusual features including a region near the N terminus that bulges away from the domain rather than pairing with the neighboring beta-strand. Some of the residues in this region make contact with VEGF, raising the possibility that this bulge could be a consequence of VEGF binding and might not be present in the absence of ligand. Here we report the three-dimensional structure of Flt-1D2 in its uncomplexed form determined by NMR spectroscopy. A semi-automated method for NOE assignment that takes advantage of the previously solved crystal structure was used to facilitate rapid analysis of the 3D NOESY spectra. The solution structure is very similar to the previously reported VEGF-bound crystal structure; the N-terminal bulge is present, albeit in a different conformation. We also report the 2.7 A crystal structure of Flt-1D2 in complex with VEGF solved in a different crystal form that reveals yet another conformation for the N-terminal bulge region. (1)H-(15)N heteronuclear NOEs indicate this region is flexible in solution; the crystal structures show that this region is able to adopt more than one conformation even when bound to VEGF. Thus, VEGF-binding is not accompanied by significant structural change in Flt-1D2, and the unusual structural features of Flt-1D2 are an intrinsic property of this domain.

Automation

Sensitive high-performance liquid chromatographic method for profiling phytoestrogens using coulometric electrode array detection: application to plasma analysis.

An HPLC method for profiling 13 phytoestrogens and their metabolites using coulometric electrode array detection was developed. Sensitivity of the method was slightly less than that of our GC-MS method, but significantly higher compared to the HPLC methods using diode-array or UV detection. Detection limits varied from 3.4 (secoisolariciresinol) to 40.3 (genistin) pg on column. Signal linearities ranged from the detection limits to 61 ng on column. Resolution values for the peak pairs varied from 1.1 (O-desmethylangolensin-anhydrosecoisolariciresinol) to 16 (daidzin-genistin). Intra- and interassay retention time variations were negligible and detector response variation was eliminated by frequent calibration. Chromatographic method was applied to plasma analyses and 6 of the 13 compounds were detected. Method accuracy for those six analytes varied from 69% (enterodiol) to 118% (genistein). Intraassay precision CVs ranged from 1.5% (enterolactone, 12.4 nmol/liter) to 14% (genistein, 245 nmol/liter) and interassay precision CVs ranged from 9.9% (daidzein, 67.4 nmol/liter) to 44% (enterodiol, 1.20 nmol/liter).

Automation