Search PubMedSearch

PubMed · 8744856

Visual function during acute hypoglycaemia.

Abstract

Hypoglycaemia symptoms are of particular interest in view of the importance of hypoglycaemia unawareness. Visual symptoms arising during acute hypoglycaemia may be the result of metabolic disturbances in the visual pathways within the central nervous system or impairment of the refractive apparatus of the eye and binocular function. This study investigated the effect of hypoglycaemia upon visual acuity, binocular interaction and contrast sensitivity. Various aspects of visual function were examined in ten normal subjects before, during and after acute insulin-induced hypoglycaemia. A simultaneous study of hypoglycaemic symptoms enabled us to relate the objective findings to the symptoms as reported by the subjects. Snellen visual acuity, fusion and stereopsis were not affected by hypoglycaemia. Five subjects noted visual disturbance. Eight developed significant impairment of contrast sensitivity, which closely matched the lowered blood glucose concentration. These observations suggest that hypoglycaemic visual symptoms are due to neuroglycopenia of central visual pathways rather than changes within the refractive apparatus or abnormality of binocular function. Although these symptoms are not a constant feature of the hypoglycaemic state, subtle impairment of visual function occurs in most cases. Contrast sensitivity testing can be useful for assessment of fine changes in visual function.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Tabandeh, L Ranganath, V Marks. Visual function during acute hypoglycaemia.. https://doi.org/10.1177/112067219600600116

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Diagnosis and treatment of exotropia with a high accommodation convergence-accommodation ratio.

BACKGROUND: Patients with exotropia often have a slow-to-dissipate fusional mechanism at near, which masks the true near deviation. Consequently, determination of the accommodation convergence-accommodation (AC/A) ratio in patients with exotropia must be based on near measurements obtained after prolonged monocular occlusion (typically 1 hour). When determined in that manner, the presence of a high AC/A ratio before surgery in an exotropic patient has been reported to be predictive of an esotropia at near after surgery. OBJECTIVE: To investigate the diagnosis and management of exotropia with a high AC/A ratio. METHODS: Three hundred four consecutive patients with exotropia were studied. In addition to the usual measurements, measurements were obtained at near after 1 hour of monocular occlusion, with and without additional +3.00-diopter lenses. Also, a gradient AC/A ratio was obtained by using additional minus lenses at distance fixation. RESULTS: One hundred fifty-four (50.7%) of 304 patients would have been thought to have a high AC/A ratio if that diagnosis was based on measurements obtained before prolonged monocular occlusion. In fact, only 22 patients (7.2%) actually had a high AC/A ratio; 132 patients (43.4%) had a pseudo-high AC/A ratio. Six of 22 patients with a high AC/A ratio underwent surgery to correct the exotropia. The presence of a high AC/A ratio before surgery had sensitivity, specificity, and positive and negative predictive values of 100% for predicting a postoperative esotropia at near associated with a high AC/A ratio. The remaining 16 patients with high AC/A ratios were treated with overcorrecting minus lens therapy (including a bifocal). Ten of them have been followed up to at least 18 years of age, by which time 9 have shown normalization of the AC/A ratio. CONCLUSIONS: Near measurements used to calculate the AC/A ratio in exotropic patients must be made after prolonged monocular occlusion. Otherwise, many patients with a pseudo-high AC/A ratio will be thought to have a true high AC/A ratio. The presence of a high AC/A ratio is infrequent in patients with esotropia, but it is highly predictive of a postoperative esotropia at near fixation.

Accommodation, Ocular

Pseudoaccommodation: BioComFold versus a foldable silicone intraocular lens.

PURPOSE: To assess the degree of pseudoaccommodation amplitude correlated with shifts along the anteroposterior axis of the BioComFold foldable intraocular lens (IOL). SETTING: Department of Ophthalmology, Hôtel-Dieu Hospital, Paris, France. METHODS: This prospective study comprised 30 eyes of 30 patients operated on consecutively for cataract by phacoemulsification and in-the-bag implantation of a BioComFold (15 patients) or a foldable control (15 patients) IOL. The BioComFold IOL has a peripheral bulging ring that pushes the optic forward during the effort to accommodate, creating a zoom effect. Pseudoaccommodation amplitude was evaluated using the blurring of controlled vision by adding spheres, with the best correction for distance vision in place. Pupil diameter was measured with a Goldmann campimeter under constant illumination. Anterior chamber depth was determined by A-scan (Paxial, Biophysic Medical) 30 minutes after cyclopentolate 1% was instilled and again 30 minutes after pilocarpine 2% was instilled. RESULTS: The difference in pseudoaccommodation amplitude and pupil diameter between the 2 groups was not statistically significant (P = .6737 and P = .4014, respectively). The IOL's forward shifts from maximal ciliary relaxation to maximal ciliary contraction were significantly greater in the BioComFold group (P = .0215). CONCLUSION: The design of the BioComFold IOL allowed greater forward optic shifts along the anteroposterior axis during the effort to accommodate. Nevertheless, this shift was not correlated with a significantly greater pseudoaccommodation amplitude.

Accommodation, Ocular