Search PubMedSearch

PubMed · 8723612

Monitoring expert system performance using continuous user feedback.

Abstract

OBJECTIVE: To evaluate the applicability of metrics collected during routine use to monitor the performance of a deployed expert system. METHODS: Two extensive formal evaluations of the GermWatcher (Washington University School of Medicine) expert system were performed approximately six months apart. Deficiencies noted during the first evaluation were corrected via a series of interim changes to the expert system rules, even though the expert system was in routine use. As part of their daily work routine, infection control nurses reviewed expert system output and changed the output results with which they disagreed. The rate of nurse disagreement with expert system output was used as an indirect or surrogate metric of expert system performance between formal evaluations. The results of the second evaluation were used to validate the disagreement rate as an indirect performance measure. Based on continued monitoring of user feedback, expert system changes incorporated after the second formal evaluation have resulted in additional improvements in performance. RESULTS: The rate of nurse disagreement with GermWatcher output decreased consistently after each change to the program. The second formal evaluation confirmed a marked improvement in the program's performance, justifying the use of the nurses' disagreement rate as an indirect performance metric. CONCLUSIONS: Metrics collected during the routine use of the GermWatcher expert system can be used to monitor the performance of the expert system. The impact of improvements to the program can be followed using continuous user feedback without requiring extensive formal evaluations after each modification. When possible, the design of an expert system should incorporate measures of system performance that can be collected and monitored during the routine use of the system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M G Kahn, S A Steib, W C Dunagan, V J Fraser. Monitoring expert system performance using continuous user feedback.. https://doi.org/10.1136/jamia.1996.96310635

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Expert systems and automatic diagnostic systems in histopathology--a review].

In this decade, the pathological information system has gradually been settled in many hospitals in Japan. Pathological reports and images are now digitized and managed in the database, and are referred by clinicians at the peripherals. Tele-pathology is also developing; and its users are increasing. However, in many occasions, the problem solving in diagnostic pathology is completely dependent on the solo-pathologist. Considering the need for timely and efficient supports to the solo-pathologist, I reviewed the papers on the knowledge-based interactive expert systems. The interpretations of the histopathological images are dependent on the pathologist, and these expert systems have been evaluated as "educational". With the view of the success in the cytological screening, the development of "image-analysis-based" automatic "histopathological image" classifier has been on ongoing challenges. Our 3 years experience of the development of the pathological image classifier using the artificial neural networks technology is briefly presented. This classifier provides us a "fitting rate" for the individual diagnostic pattern of the breast tumors, such as "fibroadenoma pattern". The diagnosis assisting system with computer technology should provide pathologists, especially solo-pathologists, a useful tool for the quality assurance and improvement of pathological diagnosis.

Expert Systems

A medical expert system approach using artificial neural networks for standardized treatment planning.

PURPOSE: Many radiotherapy treatment plans involve some level of standardization (e.g., in terms of beam ballistics, collimator settings, and wedge angles), which is determined primarily by tumor site and stage. If patient-to-patient variations in the size and shape of relevant anatomical structures for a given treatment site are adequately sampled, then it would seem possible to develop a general method for automatically mapping individual patient anatomy to a corresponding set of treatment variables. A medical expert system approach to standardized treatment planning was developed that should lead to improved planning efficiency and consistency. METHODS AND MATERIALS: The expert system was designed to specify treatment variables for new patients based upon a set of templates (a database of treatment plans for previous patients) and a similarity metric for determining the goodness of fit between the relevant anatomy of new patients and patients in the database. A set of artificial neural networks was used to optimize the treatment variables to the individual patient. A simplified example, a four-field box technique for prostate treatments based upon a single external contour, was used to test the viability of the approach. RESULTS: For a group of new prostate patients, treatment variables specified by the expert system were compared to treatment variables chosen by the dosimetrists. Performance criteria included dose uniformity within the target region and dose to surrounding critical organs. For this standardized prostate technique, a database consisting of approximately 75 patient records was required for the expert system performance to approach that of the dosimetrists. CONCLUSIONS: An expert system approach to standardized treatment planning has the potential of improving the overall efficiency of the planning process by reducing the number of iterations required to generate an optimized dose distribution, and to function most effectively, should be closely integrated with a dosimetric based treatment planning system.

Expert Systems