Abstract

Electrophysiologic tests of the sacral neuromuscular system and its suprasegmental control may be divided into EMG and methods involving stimulation (i.e., evoked potential and sacral reflex testing). The latter group of methods tests the function of defined parts of the motor or sensory nervous system, or reflex arcs. There already is ample experience with testing the somatic sensory pathways (pudendal SEP) and the (somatic) sacral reflex arc, whereas other methods (testing the motor system and tests involving visceral afferents and sympathetic efferents) need further study to establish their proper place in everyday clinical diagnostics. The application of these methods in research has led to important advances in our understanding of nervous system involvement in different pathologic conditions leading to neurogenic sacral dysfunctions. If applied in individual patients, these methods should however, be used and interpreted with restraint; they should be considered in patients with probable or proved nervous system lesions, those in whom additional clarification regarding proof of, localization of, and the nature (i.e., axonal versus demyelinative) of the lesion is relevant for diagnosis and prognosis. If applied in patients with central nervous system involvement, evoked potential studies may be used on their own; but, in the author's opinion, in patients with putative peripheral nervous system involvement these tests should be considered, as a rule, only as an extension of a needle EMG exploration. It is expected that further experience will clarify the sensitivity and specificity of the available methods. The already available methods certainly will gain a place in the operating room helping the surgeon in selected procedures involving the pelvis and particularly conus and cauda equina better to identify neuromuscular structures and to monitor their function throughout the operation in order to prevent subsequent development of lesions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D B Vodusek. 1996. Evoked potential testing.. https://doi.org/10.1016/s0094-0143(05)70323-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Cardiovascular collapse caused by electrocardiographically silent 60-Hz intracardiac leakage current. Implications for electrical safety.

BACKGROUND: The national standard for safe 60-Hz intracardiac leakage current under a single-fault condition is 50 microA. This standard is intended to protect patients from alternating current (AC) at levels below the threshold for sensation, but the minimum unsafe level for AC in closed-chest humans is not known. To determine this value, we studied 40 patients at testing of implantable cardioverter-defibrillators using a programmable source of 60-Hz AC. METHODS AND RESULTS: We applied AC for 5-second test periods in increasing strengths until ventricular fibrillation (VF) was induced or 1 mA was reached. Two current paths were tested: bipolar, between tip and ring electrodes of a right ventricular pacing catheter, and unipolar, from tip to a remote electrode. We observed a characteristic sequence of 3 responses as AC was increased: (1) intermittent ventricular capture with QRS morphology identical to pacing through the electrodes (minimum value, 20 microA); (2) continuous capture at cycle length 282+/-88 ms (minimum value, 32 microA); and (3) VF persisting after AC termination (minimum value, 49 microA). Continuous capture caused loss of pulsatile arterial pressure and cardiovascular collapse (mean arterial pressure, 32+/-8 mm Hg) for the duration of AC with no ECG evidence of AC stimulation. Thus, the clinical picture was that of hypotensive ventricular tachycardia (VT). The continuous-capture threshold was </=50 microA in 9 patients (22%) for bipolar AC and in 5 (12%) for unipolar AC. All patients showed continuous capture over a wide range for both bipolar AC (68+/-18 to 216+/-238 microA) and unipolar AC (84+/-27 to 278+/-226 microA). CONCLUSIONS: Leakage current causes cardiovascular collapse at levels below the VF threshold. Stimulation by silent AC that is neither felt nor visible on the ECG presents as hypotensive VT. In patients with intracardiac electrodes, leakage current less than or equal to the present standard of 50 microA may cause VT or VF. The safety standard for leakage current lasting >/=5 seconds should be </=20 microA. This standard should be based on the continuous-capture threshold.

Electric Stimulation

Evaluation of refractory epilepsy treated with vagus nerve stimulation for up to 5 years.

We assessed the long-term efficacy of vagus nerve stimulation (VNS) in 64 refractory epilepsy patients. After implantation, intermittent stimulation was delivered and seizure frequency and severity were counted. Average treatment time was 20 months. Nineteen of 47 patients with partial seizures, five of nine patients with idiopathic generalized seizures, and five of eight patients with Lennox-Gastaut syndrome had >50% seizure reduction. Side effects were mild. VNS is a safe and effective treatment for refractory epilepsy.

Electric Stimulation