Phase-encode reordering to minimize errors caused by motion.

Abstract

A new method for suppressing the effects of motion in MR images by reordering the acquisition of k space has been developed. Existing reordering methods suffer from image blurring. The method presented here applies specifically to translation along the phase-encoding direction, in which case it reduces both ghosting and blurring. The method is conceptually similar to a linear phase shift of k space, except that it has the advantage of not corrupting stationary structures inadvertently. The method is intended for anatomic sites in which substantial translational motion occurs along the phase-encoding direction, such as the cranial-caudal motion of the liver and kidneys. The reordering method is motivated from an analysis of factors affecting the severity of motion artifacts. The theory behind the reordering method is described and validated experimentally by imaging a moving phantom.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C K Macgowan, M L Wood. 1996. Phase-encode reordering to minimize errors caused by motion.. https://doi.org/10.1002/mrm.1910350318

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Effect of frozen storage on the creep behavior of human intervertebral discs.

STUDY DESIGN: A biomechanical study of the compressive creep behavior of the human intervertebral disc before and after frozen storage. OBJECTIVES: To determine whether frozen storage alters the time-dependent response of the intact human intervertebral disc. SUMMARY OF BACKGROUND DATA: The biomechanical properties of the intervertebral disc are generally determined using specimens that have been previously frozen. Although it is well established that freezing does not alter the elastic response of the disc, recent data demonstrate that freezing permanently alters the time-dependent mechanical behavior of porcine discs. METHODS: Twenty lumbar motion segments from 10 human spines were harvested between 12 and 36 hours postmortem. The specimens were randomly assigned to one of two groups: Group 1 was tested promptly, stored frozen for 3 weeks, then thawed, and tested a second time; Group 2 was stored frozen for 3 weeks, thawed, and then tested. Each specimen was subjected to 5 cycles of compressive creep under 1 MPa for 20 minutes, followed by a 40-minute recovery under no load. After testing each specimen was graded on a degeneration scale. A fluid transport model was used to parameterize the creep data. RESULTS: There was no statistically significant effect of freezing on the elastic or creep response of the discs. The degree of pre-existing degeneration had a significant effect on the creep response, with the more degenerated discs appearing more permeable. CONCLUSIONS: Frozen storage for a reasonable time with a typical method does not significantly alter the creep response of human lumbar discs. Freezing may produce subtle effects, but these potential artifacts do not appear to alter the discs' time-dependent behavior in any consequential way. These results may not apply to tissue kept frozen for long durations and with poor packaging.

Artifacts↗

Physician interpretation of electrocardiographic artifact that mimics ventricular tachycardia.

BACKGROUND: Patients who are misdiagnosed with ventricular tachycardia because of electrocardiographic artifact may be subjected to unnecessary procedures. The purpose of this study was to determine how often electrocardiographic artifact is misdiagnosed as ventricular tachycardia. METHODS: Physicians (n = 766) were surveyed with a case simulation that included a two-lead electrocardiographic monitor tracing of artifact simulating a wide-complex tachycardia. RESULTS: The rhythm strip was not recognized as artifact by 52 of the 55 internists (94%), 128 of the 221 cardiologists (58%), and 186 of the 490 electrophysiologists (38%). One hundred fifty-six of the 181 electrophysiologists (88%), 67 of the 126 cardiologists (53%), and 14 of the 15 internists (31%) who misdiagnosed the rhythm as ventricular tachycardia recommended an invasive procedure for further evaluation or therapy. CONCLUSIONS: This physician survey suggests that electrocardiographic artifact that mimics ventricular tachycardia may frequently result in patients being subjected to unnecessary invasive cardiac procedures. Physicians should include artifact in their differential diagnosis of wide complex tachycardias to minimize unneeded procedures.

Artifacts↗