Search PubMedSearch

PubMed · 8651137

Decrease in pacemaker incidence after orthotopic heart transplantation.

Abstract

A decrease in sinus node dysfunction and pacemaker requirement after orthotopic heart transplantation was observed over a 6.5-year period, probably indicating the effect of a learning curve. Indirect evidence suggests a traumatic genesis of sinus node dysfunction after cardiac transplantation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Kratochwill, S Schmid, J Koller-Strametz, G Kreiner, M Grabenwöger, M Grimm, G Laufer, G Heinz. 1996-04-01. Decrease in pacemaker incidence after orthotopic heart transplantation.. https://doi.org/10.1016/s0002-9149(97)89220-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Bradycardia after heart transplantation: reversal with theophylline.

OBJECTIVES: We attempted to demonstrate that theophylline, an adenosine receptor antagonist, can reverse bradyarrhythmias after orthotopic heart transplantation. BACKGROUND: Sinus node dysfunction, primarily sinus bradycardia, frequently occurs after orthotopic heart transplantation and may lead to permanent pacemaker implantation. Endogenous adenosine has been implicated as a cause of such posttransplantation bradyarrhythmia. METHODS: Twenty-nine transplant recipients (group 1) were given theophylline after bradyarrhythmias developed after transplantation. Data in these patients were compared with those in a control group of 18 patients without bradyarrhythmias (group 2) who were not given theophylline. RESULTS: The mean heart rate in group 1 increased from 62 +/- 7 to 89 +/- 10 beats/min after administration of theophylline (p < 0.0001); the mean heart rate in group 2 was 88 +/- 12 beats/min. Patients in group 1 required more days of temporary atrial pacing (3.5 +/- 1 vs. 1.5 +/- 3, p < 0.04) before the administration of theophylline than did patients in group 2. The length of hospital stay after transplantation did not differ significantly between groups 1 and 2 (17 +/- 7.5 vs. 20 +/- 16 days, p = NS). Age, gender, underlying disease, preoperative use of amiodarone, graft ischemia time or the incidence of moderate to severe rejection were not different between patient groups. CONCLUSIONS: The use of theophylline for posttransplantation bradyarrhythmias increased heart rate and facilitated the withdrawal of chronotropic support. We conclude that theophylline offers effective and specific therapy for heart transplant patients with early bradyarrhythmias, reducing the need for implantation of a permanent pacemaker.

Arrhythmia, Sinus

Permanent pacemaker lead implantation via the transhepatic route.

A 4-year-old male with transposition of the great arteries, status post-Senning repair, required placement of an atrial pacemaker for sinus node dysfunction and atrial flutter. Multiple systemic venous occlusions precluded conventional transvenous lead implantation. A transhepatic approach resulted in successful placement of an endocardial atrial pacing lead.

Arrhythmia, Sinus