Search PubMed⌕ Search

PubMed · 8645689

Labial sensory function following sagittal split osteotomy.

Abstract

A retrospective assessment of labial sensory function following sagittal split osteotomy was undertaken by a combination of record analysis, postal questionnaire and objective sensory testing. Case records for 90 sides operated upon by a single consultant surgeon between 1979 and 1992 identified a prevalence of persisting sensory changed at 2 years of 6.7%. A higher incidence of sensory change was seen in patients treated with intermaxillary fixation/upper border wires than those managed with buccal monocortical miniplates. Postal questionnaire returns for 67 consultant operated sides identified a higher incidence of sensory change than recorded in the notes. 5.9% had long term persisting anaesthesia. Another 28% had more variable subtle sensory impairment. A similar relation to method of fixation was seen. An association between duration of temporary sensory change and magnitude of forward mandibular advance was noted. Objective sensory testing validated the subjectively reported sensory status but also identified many patients self-assessed as normal had some undetected sensory impairment. Possible mechanisms for the above findings and implications for clinical practice are presented.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C A Pratt, H Tippett, J D Barnard, D J Birnie. 1996. Labial sensory function following sagittal split osteotomy.. https://doi.org/10.1016/s0266-4356(96)90141-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stacked plating for metadiaphyseal fractures of the distal radius: a technique report.

Combined injuries of the distal radius and shaft are rare, are usually caused by high energy, and pose a surgical dilemma. Surgical tactics and implants that are routinely used either for isolated fractures of the distal radius or for fractures of the radial shaft are often not applicable for this combined injury. We describe a technique of dual-stacked plating for these metadiaphyseal fractures and its use in two patients.

Bone Plates↗

Plate fixation of olecranon osteotomies.

The management of intra-articular distal humeral fractures remains a difficult surgical problem. Although an olecranon osteotomy provides excellent exposure for management of these fractures, a number of complications can occur after the creation and repair of the osteotomy including nonunion, malunion, hardware failure, and pain secondary to prominent hardware. In an effort to reduce the incidence of these complications, the senior authors now use contoured 3.5 mm reconstruction plates for the fixation of their apex-distal chevron olecranon osteotomies. Two surgeons at a single institution used this technique of exposure on a series of 17 consecutive patients with intra-articular distal humerus fractures between 1996 and 1999. In this series, all osteotomies united. There was one complication related specifically to the osteotomy: one of the screws in the plate penetrated the proximal radioulnar joint, interfering with forearm rotation; a second procedure was required to shorten the screw. Only one of the 17 patients requested plate removal during the 32 month (average) follow-up period. Plate fixation of olecranon osteotomies using a 3.5 mm reconstruction plate provides a construct with predictable healing and few complications. The overall results using this technique are comparable with other reported methods in the literature.

Bone Plates↗