Available research has not identified a superior tooth form or arrangement to fulfill the requirements of complete denture patients in the areas of comfort, function, and esthetics. Therefore, it appears logical to use the least complicated approach to fulfill these requirements. This approach begins with the development of a philosophy of occlusion and selection of a concept to satisfy the philosophy. A balanced articulation appears to be most appropriate because of tooth contacts observed during nonfunctional activities of patients. Occlusal schemes to fulfill these occlusal concepts are many and varied. In the opinion of the author, the lingualized articulation concept using tooth molds specifically designed for this concept seems to be the most logical and least complicated approach in occlusal rehabilitation of edentulous patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B R Lang. 1996. Complete denture occlusion.. https://pubmed.ncbi.nlm.nih.gov/8635628/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Mechanical stress enhances expression and production of plasminogen activator in aging human periodontal ligament cells.

Plasminogen activator (PA) converts plasminogen to plasmin, and plasmin activates the kinin cascade and latent extracellular matrix metalloproteases. The periodontal ligament serves to anchor the tooth to the alveolus and functions as a cushion between these hard tissues to migrate occlusal force during mastication. We reported previously that repeated mechanical tension force (MTF) as an experimental model of a traumatic occlusion, increased PA activity in human periodontal ligament derived fibroblast (hPLF) cells. In this study, the influence of in vitro cellular aging on MTF-stimulated PA activity in hPLF cells was studied. Aged hPLF cells produced a significantly higher PA activity when compared with those of young hPLF cells in response to MTF in a time- and magnitude-dependent manner. tPA mRNA levels in aged cells were higher than those in young cells, whereas PAI-1 mRNA remained unchanged and uPA mRNA was not detected. Because MTF-stimulated PA activity from hPLF cells was increased by in vitro cellular aging, aging of the periodontal ligament may affect the severity of the inflammation and the degradation of the extracellular matrix of periodontal ligament tissue by producing a large amount of PA in response to excessive force such as a traumatic occlusion.

Bite Force

Effect of margin design, cement polymerization, and angle of loading on stress in porcelain veneers.

STATEMENT OF PROBLEM: The clinical failure of porcelain veneers may result from stresses induced in the porcelain during mastication. PURPOSE: This study investigated whether applied stresses were large enough to cause porcelain fracture, examined the influence of the margin design, and examined whether a lack of bond in the middle, cervical, or incisal area would have any influence on stress distribution. MATERIAL AND METHODS: A 2-dimensional finite element model was made. Location and magnitude of maximum compressive and tensile stresses were calculated in porcelain veneer. RESULTS: Small differences in stress were observed in the margin portion for various cervical designs under the same conditions. An increase in stresses appeared for all situations and in all reading points with a more transverse angulation of load. A significant difference appeared between full bonding and a lack of adhesion in the middle portion, or cervical and incisal areas, of the veneer. CONCLUSION: A chamfer or shoulder preparation is recommended for porcelain veneer preparations. Careful evaluation of occlusal forces and how these forces affect the facing is indicated. It is important to receive a full bonding between the tooth and facing.

Bite Force

Energy-based evaluation of occlusion.

The purpose of this study was to establish an index for evaluating occlusal conditions using energy levels. For this purpose, first, the movement of mastication under five occlusal conditions in which the positional relationship varied mesiodistally was simulated and the energy applied to the food being masticated was calculated, based on theoretical values of computing mechanics using finite element static analysis. As a model experiment, the energy generated under each occlusal condition was then measured using the electrical output from an occlusion pressure sensor composed of pressure-sensitive rubber. By comparing the theoretical values of computing mechanics and the measured values, the changes in the energy level under occlusal conditions were consistent with the trends, and the maximum value of the energy was obtained under the occlusal condition of Angle Class I and consisting of rigid interdigitation. In conclusion, our results demonstrated that occlusal conditions can be evaluated using the energy level as an index.