Search PubMed⌕ Search

PubMed · 8607305

Caffeine-halothane accuracy in MH testing.

Abstract

The accuracy and stability of caffeine and halothane concentrations in liquid Krebs medium were examined. Caffeine-Krebs Ringer's solution in incremental concentrations from 0.25 to 10 mM (N = 8 for each concentration) was serially assayed over a three-year period. Storage was at 4 degrees C. For serial testing of halothane during a five month period, halothane 1% or 3% in carbogen was bubbled through a Krebs solution, contained in muscle baths, either using a roller pump (to eliminate vaporizer back pressure) or using carbogen at a line pressure of 4-6 lbs/in2 (27-41 kPa). Halothane in Krebs was assayed by high pressure liquid chromatography. Caffeine concentrations did not vary for 20 weeks. From then, through 60 weeks, concentrations less than 2 mM steadily diminished; after that, through 156 weeks, only 4, 8, and 10 mM were stable. When compared to the halothane concentration in gas entering the muscle baths, halothane concentration in Krebs was predictable regardless of method delivery, as long as a gas analyzer indicated the proper concentration. We conclude that caffeine solutions are stable for 20 weeks when refrigerated, and for three years at concentrations 4 mM or greater.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Hwang, K Chun, J F Antognini, G A Gronert. 1995. Caffeine-halothane accuracy in MH testing.. https://doi.org/10.1111/j.1399-6576.1995.tb04225.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The crystal structure of anhydrous beta-caffeine as determined from X-ray powder-diffraction data.

The crystal structure of the low-temperature form of anhydrous caffeine has been determined by using X-ray powder-diffraction data with a combined simulated-annealing/Rietveld method. Anhydrous caffeine crystallizes with five crystallographically independent molecules in a monoclinic C-centred unit cell with dimensions of a=43.0390(17), b=15.0676(6) and c=6.95314(14) A and a beta angle of 99.027(2) degrees.

Caffeine↗

Variability in human skin permeability in vitro: comparing penetrants with different physicochemical properties.

Appreciating and compensating for the inherent variability associated with percutaneous absorption is essential in optimizing (trans)dermal therapy. In this study, the variability in human skin permeability associated with model penetrants of differing lipophilicity (caffeine (CF), methyl paraben (MP), and butyl paraben (BP)) was examined in a standardized intra-laboratory study (Franz cell experiments) using epidermal tissue from various donors. Experimentally derived permeability coefficients (K(P)) were also compared to that derived from two skin permeation models namely, Potts & Guy and Robinson (revised) models in order to further validate the Franz diffusion method employed and also elucidate the potential permeation pathway(s) employed by the model penetrants. Intra-subject variability associated with skin permeation of the model penetrants was generally found to be lower than inter-subject variability. Experimental K(P) values were found to be the same order of magnitude as predicted by the mathematical models. Calculated residual variance suggested the Potts and Guy's model to be relatively accurate in predicting skin permeability of the two parabens whilst the Robinson (revised) model was more effective for CF. The high variability in CF permeation compared to the parabens may suggest the in vitro skin permeation of solutes becomes more sensitive to intra- and/or inter-subject variation in skin lipid content, appendageal density, and imperfections (pores, cracks) as the hydrophilic nature of the solute increases. Such variability in skin permeability suggests a difference in CF permeation kinetics relative to the parabens. As such when performing in vitro drug permeation studies, it is essential that the variability in the absorption of the model permeants, according to their physicochemical properties, is considered when they are used to normalize or standardize any resulting data.

Caffeine↗