Search PubMedSearch

PubMed · 8601924

Computerized drug interaction programs: how reliable?

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K E Kraft, F H Dore. 1996-04-10. Computerized drug interaction programs: how reliable?. https://doi.org/10.1001/jama.275.14.1087b

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

In vivo brain glucose measurements: differential normal pulse voltammetry with enzyme-modified carbon fiber microelectrodes.

The enzyme glucose oxidase was immobilized on the surface of carbon fiber microelectrodes (CFMEs) either by cross-linking in glutaraldehyde vapor or by enzyme entrapment in electropolymerized films of m-phenylenediamine or resorcinol. The cross-linked enzymatic layer was, in the given conditions, covered with an additional membrane of Nafion or cellulose acetate. The prepared glucose sensors were tested using differential normal pulse voltammetry (DNPV, in which the scan comprises successive double pulses ("prepulse and pulse"), the prepulses are of increasing amplitude, and the current measured is the differential of the current existing between each prepulse and pulse). With properly chosen DNPV parameters, the response to glucose presented a peak at a potential of about 1 V versus an Ag/AgC1-reference, owing to the oxidation of enzymatically produced hydrogen peroxide. The calibration curves obtained (peak height/glucose concentration) were linear from 0.3-0.5 up to 1.5-6.5 mM and showed a sensitivity ranging from 1.4 up to 34.5 mA M-1 cm-2, depending on the sensor type. The DNPV response to glucose exhibited an essential insensitivity toward easily oxidizable interfering substances such as ascorbic acid and acetaminophen present at physiological concentrations. Peptides, the interfering species typical of the cerebral medium, were effectively retained by the above additional membranes. Concentration values of glucose in plasma and cerebrospinal fluid, determined in vitro from the DNPV peak height, agreed well with those measured by standard procedures. In the anesthetized rat, extracellular brain concentration of glucose was also monitored during administration of either insulin or glucagon. Under such pharmacological conditions, the changes observed in the peak height were in perfect agreement with the known effects induced by both substances.

Acetaminophen

Combined HPLC, NMR spectroscopy, and ion-trap mass spectrometry with application to the detection and characterization of xenobiotic and endogenous metabolites in human urine.

The direct coupling of HPLC with NMR spectroscopy has been extended by splitting the HPLC eluent after conventional UV detection and sending part to a NMR spectrometer and part to an ion-trap mass spectrometer in a "triplehyphenated" HPLC-NMR-MS system. Combined UV, 1H NMR, and positive-ion electrospray MS detection was achieved in the continuous-flow mode using whole human urine from a subject dosed with acetaminophen. By means of HPLC-NMR-MS, the structural information available from the complementary spectroscopic techniques provided rapid confirmation of the identity of the acetaminophen glucuronide and sulfate metabolites, together with a number of endogenous metabolites. In particular, the HPLC-NMR-MS approach allowed the unequivocal identification of phenylacetylglutamine in human urine, an endogenous metabolite not previously observed in 1H NMR spectra of urine because of extensive overlap with resonances from other metabolites. The analytical advantages and complementarity of NMR and MS techniques in direct hyphenation with HPLC are discussed. The new technique of HPLC-NMR-MS will provide the scope for more comprehensive and fully automated analysis of biofluids and other complex mixtures than was previously available from single hyphenation of these instruments.

Acetaminophen