Abstract

A low-D-Dimer concentration has a high negative predictive value for thromboembolic events. Actual and proposed applications include exclusion diagnosis of DIC, DVT and pulmonary embolism (1-7), follow up of cancer therapy (8) and diagnosis of abruptio placentae(9). A variety of tests are commercially available. Unfortunately, due to differences in standardization protocols, the cut-off normal/pathological of one test can usually not be used for another(10). As was shown by Nieuwenhuizen, one way to at least reduce these discrepancies is to use patient material as a reference(11). We have used this approach to standardize the latex test Tinaquant a D-Dimer against the ELISA test Asserachrom D-Dimer.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Adema, U Gebert. 1995-10-01. Pooled patient samples as reference material for D-Dimer.. https://doi.org/10.1016/0049-3848(95)00146-i

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Sequential determination of two proteins by temperature-triggered homogeneous chemiluminescent immunoassay.

A novel protocol for performing a sequential dual-protein immunoassay, based on a temperature-triggered separation/mixing process and HRP-catalyzed chemiluminescence (CL) detection, is described. In contrast to current multilabel-based detection techniques, a single HRP label is employed in this proposed method. Herein we introduce poly(N-isopropylacrylamide) (PNIP) and magnetic beads as bimolecular immobilizing carriers to separate different targets by taking advantage of thermal response, as demonstrated by sequential detection of human IgG and IgA. PNIP is known to aggregate and precipitate out of water when the temperature is raised above the lower critical solution temperature (LCST) of 31 degrees C; thus, it can be separated from supernatant by centrifugation. Besides, magnetic beads can be separated from PNIP by magnetic force as the temperature is lower than LCST. A homogeneous noncompetitive ELISA was employed, formed by primary antibodies immobilized onto the surface of magnetic beads and PNIP, antigen as IgG and IgA in the sample, and HRP-labeled second antibodies. Moreover, highly sensitive CL detection of HRP was applied, and the detection limits of IgG and IgA were as low as 2.0 and 1.5 ng/mL, respectively. Within the calibrated amount, the protocol had excellent precision within 11% for each target and was comparable in performance to commercial single-analyte ELISAs. Furthermore, the proposed method has been successfully applied to the determination of dual analyte in real samples without cross-reaction, and a good correlation was achieved after comparison with the conventional assay for IgG and IgA in 40 human serum samples.

Enzyme-Linked Immunosorbent Assay↗

Plasma osteopontin levels in patients with head and neck cancer and cervix cancer are critically dependent on the choice of ELISA system.

BACKGROUND: The tumor-associated glycoprotein osteopontin (OPN) is discussed as a plasma surrogate marker of tumor hypoxia and as an indicator of the presence of pleural mesothelioma in asbestos-exposed individuals. The clinical introduction of plasma OPN measurements requires the availability of a reliable enzyme-linked immunosorbence assay (ELISA). METHODS: We compared previously described and currently available ELISA systems on 88 archival plasma samples obtained from patients with head and neck or cervix cancer between 20 days before and 171 after the start of radiotherapy. RESULTS: Median (range) plasma OPN levels were 667 (148.8-2095) ng/ml and 9.8 (3.5-189.5) ng/ml for a previously described and a newly marketed assay, respectively. Although results for different assays were significantly correlated (r = 0.38, p < 0.05, Spearman rank test), between-assay factors ranged from 2.0 to 217.9 (median 74.6) in individual patients. OPN levels in cervix cancer patients were comparable to those of head and neck cancer patients. CONCLUSION: Commercially available OPN ELISA systems produce different absolute plasma OPN levels, compromising a comparison of individual patient data with published results. However, different assays appear to have a similar capacity to rank patients according to plasma OPN level. A review of literature data suggests that plasma OPN levels measured even with identical ELISA systems can only be compared with caution.

Enzyme-Linked Immunosorbent Assay↗