Quality control for SPECT systems.

Abstract

A comprehensive set of acceptance tests is the basis for an effective quality control program. Acceptance tests indicate whether the scintillation camera meets published specifications but should also include evaluation of certain parameters not specified by the vendor but that can seriously affect image quality. Once a camera is "accepted," initial quality control tests serve as a benchmark for future measurements. Tomographic systems must be subjected to the same basic quality control program as planar cameras. Flood field images must be acquired and evaluated daily; spatial resolution must be tested once each week. Less frequently, parameters such as multiple-window spatial registration, collimator uniformity, system sensitivity, and camera "dead time" should be evaluated. Single photon emission computed tomographic systems require additional tests to ensure optimum performance. Center-of-rotation calibration and verification of detector registration are needed to avoid losses of spatial resolution. Flood corrections based on high-count images eliminate residual detector nonuniformiaties and correct for subtle collimator defects. Pixel size must be calibrated to avoid errors in attenuation correction and distortion when cardiac and brain reorientation software is used. Completed clinical studies must be checked for unacceptable patient movement and incomplete views. A quality control program may be time-consuming, but, from the standpoint of maximum benefit to patients and confidence in clinical interpretations, there is no alternative.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L S Graham. 1995. Quality control for SPECT systems.. https://doi.org/10.1148/radiographics.15.6.8577970

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Postmortem examination of vascular lesions in cognitive impairment: a survey among neuropathological services.

BACKGROUND AND PURPOSE: A full appreciation of the presence of cerebral vascular lesions in cognitively impaired patients can be ultimately reached at the neuropathological level. However, there are no detailed guidelines regarding what neuropathologists should look for at autopsy in cases of suspected vascular dementia or vascular cognitive impairment. We aimed at surveying the postmortem neuropathological procedures used in different centers in examining brain lesions of presumable or possible vascular origin in cognitively impaired patients. METHODS: Thirteen laboratories participated in the survey by filling in a semistructured questionnaire. We reviewed sampling and histology procedures in use and the neuropathological definitions of some of these lesions. Neuropathological criteria for the definition of a vascular origin of the dementing process were also surveyed. RESULTS: A large variability across centers was observed in the procedures used for the neuropathological examination and the histology techniques. Heterogeneity existed also in the definition of commonly found lesions (eg, white matter alterations, small vessel disease), interpretation of whether or not the lesions were reputed to be of vascular origin, and consequently in the interpretation of the cause of cognitive decline. CONCLUSIONS: The appreciation of the presence of neuropathologically verified vascular lesions in cognitively impaired cases may be heavily influenced by the laboratory tools used and also by the heterogeneity of the criteria applied in different centers. Harmonization of neuropathological procedures is badly needed in the field of vascular dementia and vascular cognitive impairment to better understand the association between various vascular lesions and clinical symptoms such as cognitive impairment.

Artifacts↗

Comparison of the effectiveness of two liquid-based Papanicolaou systems in the handling of adverse limiting factors, such as excessive blood.

BACKGROUND: Excessive blood may compromise gynecologic Papanicolaou (Pap) smears. Liquid-based cytologic techniques have been developed in part to address this problem. In the current study, conditions of excessive blood were simulated to compare the ability of two liquid-based systems, ThinPrep and SurePath, to satisfactorily process specimens in the presence of this potentially limiting factor. METHODS: Equal volumes of washed epithelial cells derived from pooled residues of liquid Pap vials were added to a series of ThinPrep and SurePath vials. Increasing volumes of freshly drawn, packed erythrocytes were added to the vials in progressive amounts from 50 microL or 100 microL up to 3000 microL. The vials were processed on their respective instruments according to U.S. Food and Drug Administration-approved procedures for a total of six test runs. The cellularity of the slides was measured by averaging epithelial cell counts in a total of five 40x fields. RESULTS: SurePath preparations were uncompromised by blood until aliquots from 1000 microL to 3000 microL were reached. The ThinPrep system invariably was overwhelmed by the first 50-microL or 100-microL aliquot of blood, with epithelial cell counts dropping immediately to near zero. CONCLUSIONS: The cell enrichment process of the SurePath system capably handled significantly greater amounts of potentially obscuring blood than the membrane filtration method of the ThinPrep system, which was compromised by as little as <or= 1 drop of packed erythrocytes (1 drop = 65 microL).

Artifacts↗