Physiologic diagnosis and function in asthma.

Abstract

Asthma is a condition in which there is airway hyperresponsiveness, with the propensity for widespread, reversible airways narrowing on exposure to diverse inciting factors (triggers). Inhalation of nonspecific agents such as methacholine or histamine leads to bronchoconstriction in most cases, and in some, the bronchoconstriction follows exposure to specific agents such as antigen or occupational irritants. Chest tightness and cough, which are the most common symptoms of asthma, are probably the result of inflammation mucus plugs, edema, or smooth muscle constriction in the small peripheral airways. Because major obstruction of the peripheral airways can occur without recognizable increases of airway resistance or FEV1, the physiologic alterations in acute exacerbations are generally subtle in the early stages. Poorly ventilated alveoli subtending obstructed bronchioles continue to be perfused, and as a consequence, the P(A-a)O2 increases and the PaO2 decreases. At this stage, ventilation is generally increased, with excessive elimination of carbon dioxide and respiratory alkalemia. In the more severe exacerbation, lung volume is increased and the static volume-pressure curve is shifted up (lung volume is greater) and to the left (pressure is lower) while the shape of the curve is unaltered. The airway obstruction is reversible and there is generally improvement in air flow rates following administration of beta-agonists and anti-inflammatory agents. The changes in mechanical properties are also reversible, and therapeutic intervention usually results in a shift of the PV curve downward toward the normal position, for example, a decrease in TLC and an increase in the elastic recoil pressure at any particular lung volume. Failure to take these changes into account may underestimate the impact of therapy. The PaO2 decreases (and the P(A-a)O2 increases) as the work of breathing increases, and when it becomes excessive (and/or the FEV1 falls below 20% to 25%), the PaCO2 begins to increase. Therefore, in any patient with asthma, a decreasing PaO2 and an increasing PaCO2, even into the normal range, indicates severe airway obstruction that is leading to respiratory muscle fatigue and patient exhaustion.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R M Cherniack. 1995. Physiologic diagnosis and function in asthma.. https://pubmed.ncbi.nlm.nih.gov/8565401/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Correction of compliance and resistance altered by endotracheal tube leaks and non-linear pressure/volume-relationships.

Measurements of lung compliance (C) and resistance (R) are influenced by endotracheal tube leaks (ETTL) as well as non-linear pressure/volume relationships (P/V relationship). To keep C and R reliable, we developed an algorithm to mathematically correct inspiratory and expiratory volume (V) and flow. In this study, a ventilated lung model for non-linear P/V relationship with adjustment of an increasing ETTL was studied. In addition, the recordings (airway pressure, flow, and volume) of 21 infants (median weight: 1,220 g, range: 640-2,160 g, with a median leak size of 32%, range: 24-56%) were investigated. C and R were calculated continuously from the recordings of flow, volume, and airway pressure over time according to the changing volume. A method especially developed for the analysis of non-linear pressure-volume-relationship (APVNL) was employed. C and R affected by leaks were corrected applying the newly developed mathematical algorithm and compared with measurements without leakage. C could be corrected up to a leak of 80% and R up to 55% leak at half tidal V for the model with non-linear P/V-R. C and R without leak and after leak correction did not differ significantly in all infants where the APVNL method was applied (P > 0.05).

Airway Resistance↗

Parenchymal tethering, airway wall stiffness, and the dynamics of bronchoconstriction.

We do not yet have a good quantitative understanding of how the force-velocity properties of airway smooth muscle interact with the opposing loads of parenchymal tethering and airway wall stiffness to produce the dynamics of bronchoconstriction. We therefore developed a two-dimensional computational model of a dynamically narrowing airway embedded in uniformly elastic lung parenchyma and compared the predictions of the model to published measurements of airway resistance made in rats and rabbits during the development of bronchoconstriction following a bolus injection of methacholine. The model accurately reproduced the experimental time-courses of airway resistance as a function of both lung inflation pressure and tidal volume. The model also showed that the stiffness of the airway wall is similar in rats and rabbits, and significantly greater than that of the lung parenchyma. Our results indicate that the main features of the dynamical nature of bronchoconstriction in vivo can be understood in terms of the classic Hill force-velocity relationship operating against elastic loads provided by the surrounding lung parenchyma and an airway wall that is stiffer than the parenchyma.

Airway Resistance↗

Use of dynamic compliance for open lung positive end-expiratory pressure titration in an experimental study.

OBJECTIVE: We tested whether the continuous monitoring of dynamic compliance could become a useful bedside tool for detecting the beginning of collapse of a fully recruited lung. DESIGN: Prospective laboratory animal investigation. SETTING: Clinical physiology research laboratory, University of Uppsala, Sweden. SUBJECTS: Eight pigs submitted to repeated lung lavages. INTERVENTIONS: Lung recruitment maneuver, the effect of which was confirmed by predefined oxygenation, lung mechanics, and computed tomography scan criteria, was followed by a positive end-expiratory pressure (PEEP) reduction trial in a volume control mode with a tidal volume of 6 mL/kg. Every 10 mins, PEEP was reduced in steps of 2 cm H2O starting from 24 cm H2O. During PEEP reduction, lung collapse was defined by the maximum dynamic compliance value after which a first measurable decrease occurred. Open lung PEEP according to dynamic compliance was then defined as the level of PEEP before the point of collapse. This value was compared with oxygenation (Pao2) and CT scans. MEASUREMENTS AND MAIN RESULTS: Pao2 and dynamic compliance were monitored continuously, whereas computed tomography scans were obtained at the end of each pressure step. Collapse defined by dynamic compliance occurred at a PEEP of 14 cm H2O. This level coincided with the oxygenation-based collapse point when also shunt started to increase and occurred one step before the percentage of nonaerated tissue on the computed tomography exceeded 5%. Open lung PEEP was thus at 16 cm H2O, the level at which oxygenation and computed tomography scan confirmed a fully open, not yet collapsed lung condition. CONCLUSIONS: In this experimental model, the continuous monitoring of dynamic compliance identified the beginning of collapse after lung recruitment. These findings were confirmed by oxygenation and computed tomography scans. This method might become a valuable bedside tool for identifying the level of PEEP that prevents end-expiratory collapse.

Airway Resistance↗